background image

unit deScriptiOn 

The Miro Decorator Wireless DRD3 Switch incorporates an electro-mechanical 

relay that switches the load safely using patented zero-crossing technology. 

Miro Wireless

Miro wireless devices use radio signals to communicate with each other  
to control lighting and other types of electric loads in selected areas. Miro 

wireless devices use the 900MHz band for high-speed control communication. 

Using the patented “frequency-agile” Top Dog™ technology, Miro wireless 

devices avoid interference with other 900MHz devices, such as cordless 

phones and baby monitors.

load types

Use the DRD3 for the following load types, up to the maximum load rating for 

the input voltage:
•  Conventional (non-dimmable) fluorescent ballasts
•  Discharge lighting fixtures
•  Fixtures with integral dimmers
•  AC motors and pumps (120VAC only)

cAutiOn

to reduce the risk of  

overheating and possible  

damage to other equipment, do not 

install to control a receptacle.

cAutiOn

Afin de réduire le risque de 

surchauffe et la possibilité 

d’endommager d’autres  

matériels, ne pas installer  

pour commander une prise.

Summary of Contents for DRD3

Page 1: ...or Yellow flashing LED Included in the Group Green flashing LED NOT included in the Group If you get to a device and it is NOT flashing the 5 minute binding process timer may have expired Go back to s...

Page 2: ...has another house ID Reset it to the factory default so that it can be bound to the desired house ID Resetting to factory defaults is described in the I need to start over issue If LED is solid yello...

Page 3: ...e separation between the equipment and receiver Connect the equipment to an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV tec...

Page 4: ...20VAC 1500W 1 4hp 277VAC 3000W Load Type Compatibility Non dimmable fluorescent ballasts Discharge lighting fixtures Fixtures with integral dimmers AC motors and pumps U S Patent 5 804 991 Other paten...

Page 5: ...gile Top Dog technology Miro wireless devices avoid interference with other 900MHz devices such as cordless phones and baby monitors Load Types Use the DRD3 for the following load types up to the maxi...

Page 6: ...wires will be connected to the same terminal on a Miro device both wires must be the same gauge 12AWG or 14AWG 4 Wire the LINE black LOAD NEUT white and GND green or bare supply and load wires to the...

Page 7: ...solid green about 2 seconds All device LEDs in the House change to solid green indicating house binding is complete Adding a Device to an Existing Installation If you re adding or replacing a device...

Page 8: ...omatically return to the state that they were in immediately prior to loss of power All configuration and scene control information is preserved DCO DIMMER BOTTOM FINGER When you see in the instructio...

Page 9: ...G SPECIFICATIONS OR REQUIRE ADDITIONAL FILE FORMATTING PLEASE CONTACT Mary Jo Sowinski Phone 408 486 7511 Email maryjo sowinski wattstopper com Drawing 07477 Orig Drawing Date 16 MAR 07 Rev 2 Revision...