5
Operation
Switch on
The green «power on» indicator light lights up.
The «detection/fault» indicator light flashes yellow/red for a few minutes and then
goes out
.
(time required for the detector to initialise)
Detection of gas
The «detection/fault» red indicator light lights up and remains red,
The integral buzzer sounds intermittently,
The state of the internal relay changes,
An In One scenario command is emitted by powerline carrier (CPL) to the In One
product(s) associated during learning.
TEST mode
Pressing the TEST button simulates gas detection until it is released
(the TEST button is accessible only when the cover is removed).
Fault
The yellow “detection/fault” indicator light blinks.
The buzzer beeps twice every minute.
- The gas detectors Cat. Nos
7756 78 / 7756 79 are compatible with the scenario controller Cat. No. 7756 19
.
- They can be linked to radio products via the PLC/RF modular interface.
Definitions
Learning:
the procedure which enables a scenario to be defined and save.
Scenario:
a set of controls carried out simultaneously on the various receivers which have been linked to the
transmitter during the learning procedure