08/18
LE10792AAA
LEG1939
Disclaimers
1. This product must be installed and used as per these instructions.
2. This product should only be cleaned with a damp cloth. Cleaning agents and solvents should not be used.
3. The IP rating of this product is only valid when installed on a flat and non-porous surfaces. Additional sealing may be required for irregular surfaces. An IP rating of IP44 is generally
considered suitable for external walls with supplementary protection such as overhanging eaves.
4. This product has been designed to minimise the effects of interference from off peak electricity signals. Interference in the form of light flicker is still possible in some cases
depending on proximity to the signal injection point.
5. The fixing screws on this product should be tightened to a maximum torque of 0.8Nm. Over tightening may damage the product.
6. This product is not dimmable.
7. This product contains no serviceable parts and no attempt should be made to repair this product. If the product is faulty it should be discarded.
8. Severe electromagnetic interference from other products may cause malfunction of this product.
9. The material in this product may vary in colour from batch to batch. Colour matching from one batch to another cannot be guaranteed.
10. Electrical installations periodically receive transient over voltages. This product has been designed to minimise the effect of such voltages on connected equipment. It may not give
full protection for extreme over voltage transients such as those resulting from a close lighting strike.
11. This product is not suitable for installation in hazardous and/or corrosive areas.
12. Lamp LED life is an average and will be reduced by frequent switching.
13. This product utilises intellectual property in the form of registered designs, trademarks, and/or patents. Such intellectual property remains the property of Legrand in all cases.
14. This product has been designed to operate in ambient temperatures –5 C to 25 C, occasionally reaching 35 C.
15. Legrand reserves the right to modify the specifications of this product at any time.
Warranty
Legrand warrants this product for a period of 5 years from the date
of purchase when used in accordance with these instructions and
considering the disclaimers listed herein.
These goods come with guarantees that cannot be excluded under
the Australian and New Zealand Consumer Laws.
You are entitled to a replacement or a refund for a major failure
and for compensation for any other reasonably foreseeable loss or
damage. You are also entitled to have the goods repaired if the goods
fail to be acceptable quality and the failure does not amount to a
major failure.
See the Warranty card enclosed with this product for further details.
Customer Service
For all Customer Service and Technical Support
please call Monday to Friday during business hours.
Legrand Australia
1300 369 777
www.hpm.com.au
Legrand New Zealand
0800 476 009
www.hpm.co.nz
ABN: 31 000 102 661
Where to fit your floodlight
Installation is to be made in dry weather conditions.
Always mount the floodlight in a sheltered position, i.e under the eaves of the house. Ideally the floodlight should be mounted 1.8-2.5m above the area to be illuminated.
Do not operate in close proximitiy to combustible materials or substances affected by heating or drying.
Keep a minimum distance of 0.8m between the PAR38 lamps and adjacent objects.
Installation
For installation refer to Fig.1
1. Installation must be carried out by a licensed electrician.
2. Switch power off at the meter box to isolate the circuit.
3. Unscrew the
Fixing Cover Screws
then remove the cover and
Gasket Piece
.
4. Remove the
Cable Anchorage and Terminal Block
.
5. Use the plastic back box to mark the position of the screw holes onto the mounting surface. Drill the wall to a depth of about 4cm and fit the wall plugs (supplied). Care should
be taken to avoid drilling or screwing into concealed electrical wiring.
6. Connecting the Power Cable to the
Terminal Block
, refer to the relative symbol in Fig1. Ensure the cable passes through the
Cable Gasket
.
7. Affix the back box to the mounting surface with the
Mounting Wall Screws
(supplied).
8. Re-fit the
Terminal Block
and
Cable Anchorage
.
9. Re-fit the cover.
10. Insert the PAR38 bulbs (not supplied). Please ensure the sealing rubber is placed on the lamp holders prior to the installation of the PAR38 lamps.
Important:
1) Loosen all lock nuts and screws and lamp holders before making
any adjustments.
2) No earth connection is required.
3) When adjusting lamp holders, ensure the PAR38 lamps are
not touching.