background image

INSTRUCTION / INSTALLATION SHEET 

Selective Call Intercom Distribution 
Module (P/N IC5010) 

 

IS-1507214 Rev. C 

 
301Fulling Mill Road, Suite G 
Middletown, PA 17057 
Phone (800) 223-4162 / Fax (717) 702-2546 
www.legrand.us 

©Copyright 2014 by Legrand All Rights Reserved. 

Page 1 of 4 

 

1. Introduction  

 

The Legrand Selective Call Intercom Distribution Module (P/N IC5010) is a single bay module that supports 
the audio, power and control requirements of up to 8 units in any combination of Room, Door and Patio (see

 

Figure 1

).   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

2. Description  

 

The Selective Call Intercom Distribution Module is located in the enclosure and connected to each Room, 
Door and Patio Unit via a single Cat 5 cable. Up to eight units of any combination are supported by each 
module and modules may be cascaded three times, for a total system support of up to 32 Units. The RJ45 
jacks labeled “1-8” are used for the various Units, with jack 8/V1 supporting Video Door Units. The jacks 
labeled “IN” and “OUT” are used for cascading modules. The jack labeled “AUDIO INT” is used to connect to 
the lyriQ™ Audio Distribution System to automatically mute the whole house audio when the Intercom system 
is utilized. The “VIDEO OUT” RCA jack is used to output images from a Video Door Unit. The Module comes 
with a single bay bracket for mounting in an On-Q style enclosure. 
 

NOTE: The maximum Cat 5 cable run distance between the SCI Module and another unit (Module, 
Door, Patio or Room Unit) is 330’ with the following exception. One Door or Patio Unit may be placed 
up to 1000’ (up to 650’ for a Video Door Unit) from the SCI Module, but it needs to be locally powered 
and Legrand needs to be informed of and pre-approve this type of installation. If the Cat 5 run is 
buried in an underground conduit, it should maintain a 16” separation from any 110VAC wiring. 
Additional SCI Modules are recommended to be placed in the same enclosure, powered from the 
same power strip, and interconnected with the shortest Cat 5 connections possible.

  

 

 

3. Installation  

 

Installation of the Selective Call Intercom Distribution Module is best accomplished at multiple times during 
new construction, at “Rough-in” before the drywall is installed, and at “Trim-out” after the drywall is installed 
and painted

 

A.   “Rough-in” steps: 
  

1.  Run a single Cat 5e cable from the Enclosure where the Selective Call Intercom Distribution Module will 

be installed to each of the 2 gang boxes at the eventual Room, Door and Patio Unit locations. 

 

 
 

Figure 1 