background image

www.kenall.com  |  P: 800-4-Kenall  |  F: 262-891-9701  |  10200 55th Street Kenosha, Wisconsin 53144, USA         

This product complies with the Buy American Act: manufactured in the United States with more than 50% of the component cost of US origin. It may be covered by patents 
found at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. ©2019 Kenall Mfg.Co. 

2

INSTALLATION INSTRUCTIONS

NOVA-F-0851_091118

Surface Corder Adapter for Conduit

1.  Read all fixture markings and labels to ensure correct installation of the fixture. Additional information may be 

located on the fixture, separate from this instruction sheet, regarding orientation and mounting restrictions. 

When mounting corner adapter to wall, adapter must be oriented in the corner so that the ceiling and wall can 

be use as mounting surfaces.

2.  Disconnect power to the circuit before wiring fixture.
3.  Locate and drill 6 pilot holes in mounting surface. Use surface corner adapter as template using holes in 

adapter. Using 1/4-20 fasteners and anchors appropriate for the mounting surface, (not supplied), mount 

surface adapter to building.

4.  Connect fixture leads to power supply leads using connectors suitable for the gauge and number of wires being 

used (not included). Connections are to be made in the surface adapter. Black fixture lead connects to the 

supply conductor, white fixture lead connects to the neutral supply conductor, and the grounding wire must be 

connected to a suitable ground.

5.  Mount wired fixture baseplate to adapter using the six No. 1/4-20 × 1" screws. Install lamp. Mount diffuser/

refractor to base using Torx

®

 fasteners (included) and 9500 screwdriver (ordered 1separately).

NOTE: To insure the fixtures watertight integrity, especially if the fixture is mounted in direct exposure to the 

elements, caulk between the mounting surface and base using a high quality caulking material.

CUSTOMER SERVICE

For technical assistance, call 1-800-4KENALL (1-800-453-6255). For additional instructions,  

go to www.kenall.com/Installs

For warranty information visit www.kenall.com/Resources/Certified-Performance-Warranties

WARRANTY

Reviews: