Important Notices!
Thank you for choosing LEGRAND UPS System to supply your Critical Application.
This manual contains important information about commissioning, usage and technical properties of the
UPS. It also contains safety information for operator and instructions to secure your critical load. Applying
the recommendation detailed in this manual is necessary to use UPS safely and correctly.
The manufacturer reserves the rights to change the t
echnical specifica
tions
and design without notice.
LEGRAND reserves the rights to change the information in this document
without notice. Refer to
http://ups.legrand.com/
web site to dowload last
release and translations.
Units that are labelled with a CE mark comply with the Standard: EN 62040-1 and EN 62040-2.
Read the manual completely before working on this equipment!
Keep this manual in UPS’s front cover’s pocket for easy consultation!
Reproduction, adaptation, or translation of this manual is prohibited without prior
written permission of LEGRAND Company, except as allowed under the copyright laws.
18
18
6. Installation
When the UPS is delivered, examine the packaging and product carefully to see if any damage occurred
during transport.
If either possible or ascertained damage is found report it immediately to:
• the carrier;
• LEGRAND Technical Assistance Centre.
Make sure that the unit received corresponds to the material
specified
on the delivery document. The
UPS KEOR T EVO packaging protects the equipment against mechanical and environmental damages. For
greater protection it is also wrapped in a transparen
t film.
Check if the following are provided with the equipment
• UPS
• Installation & Operating Manual
• Key for door
• Battery fuses (three pieces)
• Plinths
Before the installation, please check if your UPS is customized following your
special requirements (if any).
6.1.
Models and Dimensions
UPS Type
Dimension (HxWxD) (mm)
Net Weight (Kg)
Internal Batteries Type
UPS KEOR T EVO 10 KVA 1345H P0
1345 x 400 x 800
122
No battery
UPS KEOR T EVO 10 KVA 1345H P1
1345 x 400 x 800
261
60 blocks 7 AH
UPS KEOR T EVO 10 KVA 1345H P2
1345 x 400 x 800
283
60 blocks 9 AH
UPS KEOR T EVO 10 KVA 1650H P3
1650 x 400 x 800
426
120 blocks 7 AH
UPS KEOR T EVO 15 KVA 1345H P0
1345 x 400 x 800
127
No battery
UPS KEOR T EVO 15 KVA 1345H P1
1345 x 400 x 800
268
60 blocks 7AH
UPS KEOR T EVO 15 KVA 1345H P2
1345 x 400 x 800
288
60 blocks 9 AH
UPS KEOR T EVO 15 KVA 1650H P3
1650 x 400 x 800
431
120 blocks 7 AH
UPS KEOR T EVO 20 KVA 1345H P0
1345 x 400 x 800
134
No battery
UPS KEOR T EVO 20 KVA 1345H P1
1345 x 400 x 800
275
60 blocks 7AH
UPS KEOR T EVO 20 KVA 1345H P2
1345 x 400 x 800
296
60 blocks 9 AH
UPS KEOR T EVO 20 KVA 1650H P3
1650 x 400 x 800
477
120 blocks 9 AH
UPS KEOR T EVO 30 KVA 1345H P0
1345 x 400 x 800
141
No battery
UPS KEOR T EVO 30 KVA 1345H P1
1345 x 400 x 800
302
60 blocks 9 AH
UPS KEOR T EVO 30 KVA 1650H P2
1650 x 400 x 800
441
120 blocks 7 AH
UPS KEOR T EVO 30 KVA 1650H P3
1650 x 400 x 800
484
120 blocks 9 AH
UPS KEOR T EVO 40 KVA 1650H P0
1650 x 600 x 900
238
No battery
UPS KEOR T EVO 40 KVA 1650H P1
1650 x 600 x 900
538
120 blocks 7 AH
UPS KEOR T EVO 40 KVA 1650H P2
1650 x 600 x 900
573
120 blocks 9 AH
UPS KEOR T EVO 40 KVA 1650H P3
1650 x 600 x 900
740
180 blocks 9 AH
UPS KEOR T EVO 60 KVA 1650H P0
1650 x 600 x 900
258
No battery
UPS KEOR T EVO 60 KVA 1650H P1
1650 x 600 x 900
590
120 blocks 9 AH
UPS KEOR T EVO 60 KVA 1650H P2
1650 x 600 x 900
755
180 blocks 9 AH
Table.3