Important Notices!
Thank you for choosing LEGRAND UPS System to supply your Critical Application.
This manual contains important information about commissioning, usage and technical properties of the
UPS. It also contains safety information for operator and instructions to secure your critical load. Applying
the recommendation detailed in this manual is necessary to use UPS safely and correctly.
The manufacturer reserves the rights to change the t
echnical specifica
tions
and design without notice.
LEGRAND reserves the rights to change the information in this document
without notice. Refer to
http://ups.legrand.com/
web site to dowload last
release and translations.
Units that are labelled with a CE mark comply with the Standard: EN 62040-1 and EN 62040-2.
Read the manual completely before working on this equipment!
Keep this manual in UPS’s front cover’s pocket for easy consultation!
Reproduction, adaptation, or translation of this manual is prohibited without prior
written permission of LEGRAND Company, except as allowed under the copyright laws.
4
6
44
7.1.1.
Colour Graphical Touchscreen
Energy Flow Diagram/Modes Of Operation
and
Menus
are displayed on LCD.
The description of the symbols in the ener
gy flo
w diagram:
Bypass Input:
If Bypass voltage is OK and synchronizes with inverter; it lits Green, If Bypass voltage is
OK and not synchronizes with inverter; it lits Orange.
Rec
tifier I
nput:
If Input voltage is OK, it lits Green.
Rec
tifier
:
Converts AC voltage at the input into DC voltage. You may reach the rec
tifier
measurements
by touching it.
Bypass Line:
Shows that the loads are supplied via Bypass and line colour is Orange. If UPS is on Eco
Mode it is Green.
Battery:
Shows battery conditions. If it is discharging the indicator goes down, if it is charging the
indicator goes up. You may reach the battery/DC measurements by touching it.
Inverter:
Converts DC voltage into AC voltage. You may reach the output measurements by touching
it.
Operation Mode Information:
Shows UPS’s current operation mode.
Load:
Shows the percentage of the load as numerical and graphical information. If there is overload at
the output the load graphic lits Red. You may reach the output power measurements by touching it.
Menu:
You may reach the menus by touching it.
C
onfigur
ation:
It indicates if UPS is in parallel or single operation c
onfigur
ation. In Single Mode; there
is no symbol.
Time:
It indicates the time.
Circuit Breaker:
It appears if battery Fuse is in “OFF” position or battery fuse has blown. If battery Fuse
is in “ON” position; the circuit breaker icon is not displayed, instead battery capacity percentage is
displayed.
Alarms:
If there is an alarm on UPS this icon appears and informs the user by
flashing
. You may reach
the alarms by touching it.
Exclamation Mark:
Indicates that there is a problem where the icon appears.
Transfer:
Indicates that transfer to bypass is disabled.
Wrench:
Indicates that UPS requires Periodic Preventive Maintenance.
Temperature:
Indicates ambient temperature of UPS is too high.
Generator Mode:
Indicates UPS operates on Generator Mode.
10
1
2
3
14
5
6
12
14
13
18
4
16
15
8
11
17
7
9
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Figure.7.1.1-1