Astronomical/annual time switch
AstroRex DY64
0047 70 /74
N 292221/03
3
4
L
N S >1
ON
AUTO
OFF
ON
AUTO
OFF
ON
AUTO
OFF
ON
AUTO
OFF
1
2
3
4
2
1
4
2
1
4
2
1
4
2
1
4
120V/230V~50/60Hz
047 70
120V/230V 50/60Hz
R6a -20T
+
M
˜
M
˜
Overview
Day, time, date
Switch state
Function
Channel number
Socket for
data key
Ref. 0047 81
Separate
manual switch
for each
channel
1800W
100W
1800W
+
1400VA
1800W
2300W
1x 58W 7µF
3600W
+
+
c
R
One-week overview of the
programmed switching times.
Resolution: 0.5 h
Lithium battery module
Ref. 0047 82
Menu selection, back in menu,
Actuation >1s = operating display
Confirm a selection or accept
a parameter setting
• Selection of a menu item or set a parameter.
• Channel selection
!
Safety notes
This product may be installed only by a qualified electrician. Non-compliance may result in a fire hazard or electric shocks. Before installati-
on, read the operating instructions and observe the product-specific requirements for the installation location. Use only original spare parts for repair and mainte-
nance. All Legrand products may be opened and repaired only by specially trained Legrand personnel. Unauthorised opening and repair by other persons will invali-
date all claims for liability, replacement or warranty services. When operated from the mains voltage, the time switch may not be used to switch safe extra-low voltages
(SELV). When The device contains a Li-SOCl2 cell. When the product reaches the end of its life, this cell must be correctly removed and disposed of in accordance
with national legislation and the requirements of environmental protection.operated from a safe extra-low voltage, it may not be used to switch mains voltages.
Technical data
0047 70
0047 74
Supply voltage:
120 / 230V 50/60Hz
24 AC/DC
Delay time:
0 … 23 h 59 min 59 s
Power consumption:
approx. 0,3…2 W
approx. 3…4 W
Local coordinates:
Resolution 1°
Relay outputs 1- 4:
4 changeover contacts 16A 250V~ cos
ϕ
= 1
Battery reserve:
5 years
Accuracy:
± 0,2 s/day under typical installation conditions
Storage temperature: - 20°C to +60°C
single-strand
multi-strand
Operating principle:
Typ 1.B. S. T. IEC/EN 60730-2-7
Wire cross-sections:
1,5...4 mm
2
1,5...2,5 mm
2
Operation in a normal environment
Programs
4 channels x 3 program types x 28 programs
Degree of contamination:
2
Control signal for channel 1:
supply voltage, referred to neutral
Installation:
in distribution panel
Control-pulse duration:
> 200ms
Control-wire length:
max. 50m
Rated impulse voltage
4 kV
0,33 kV
GB