background image

3B

PROGRAM / YEAR

This menu item permits the input of (additional) annual programs which are to be executed only during a specified period. These programs and 
the weekly programs of the same channel are ORed together as described above.
The period during which a program is to be executed is defined by entering a start date and an end date.
• The option EVERY YEAR should be selected if the additional program is to be executed during the same period of each year  
  (e.g. Christmas, national holidays, birthdays, etc.).
• The option ONCE should be selected if the additional program is to be executed only during a single period (e.g. vacation period), but the  
  start and end dates of this period are different in each year.

Sample YEAR program

Channel 2 is to be activated each year on at 09:00 hours on 01.11. and deactivated at 23:00 hours.

PROGRAM / WEEK

This menu item is provided for the simple input of programs which are to be repeated weekly (such as switching of lights and boilers).
A weekly program consists of an ON time, an OFF time and the associated ON and OFF days.
• MON TO SUN: the days of the week are already assigned and you only need to set the ON and OFF times. This is used where the same  
  program is to be executed on every day of the week.
• INDIVIDUAL: you can assign the ON and OFF times to any desired days. This is used where the same program is to be executed only on  
  certain days of the week or different programs are to be executed on the various days.

OR function
The programs defined for each channel are ORed together. In other words, the output will be active if this is defined in any of the programs.
Example: channel 1

Sample WEEK program

The timer is to switch on at sunset on each day of the week and switch off at sunrise.

ON at sunset

OFF at sunrise

ON / OFF at programmed time

Prog. 1
Prog. 2

Channel-1 relay

3A

Summary of Contents for LEXIC AstroRex DY64

Page 1: ...ised opening and repair by other persons will invali date all claims for liability replacement or warranty services When operated from the mains voltage the time switch may not be used to switch safe...

Page 2: ...to 30 minutes the time switch will switch 30 minutes before sunrise and 30 minutes before sunset Offset Setting 2 D Factory setting 8 E 52 N The MINUS key is used to adjust the westward longitude valu...

Page 3: ...at 23 00 hours PROGRAM WEEK This menu item is provided for the simple input of programs which are to be repeated weekly such as switching of lights and boilers A weekly program consists of an ON time...

Page 4: ...annel switches only as defined in the exception program Option INDIVIDUAL the exception program is active from 00 00 hours on the start date to 24 00 hours on the end date During this period the outpu...

Page 5: ...itch on the outside lights of a church from 17 00 00 to 24 00 00 on each Sunday in the period 1 December to 31 December An existing weekly program is to be supplemented with additional switching times...

Page 6: ...ing the Christmas holiday period of each year i e from 18 00 00 on 23 December to 6 00 00 on 27 December ONCE MON TO SUN P p Day month year from 0 00 00 hours Day month year to 24 00 00 hours On each...

Page 7: ...together The exception program is overriding within its defined period of activity YEAR program The various weekly and annual programs are ORed together The various annual programs are ORed together...

Page 8: ...ASSIVE 7 Reset Note A reset clears the entire memory which means that all previously set data will be lost Press and hold all four keys together for about 2 seconds then release them After a reset the...

Page 9: ...ograms for this channel specifies otherwise 9 Control input with delaytime 0 23h 59min 59s Setting the delaytime Control input 0 23h 59min 59s Switched output Changing the lithium battery module Impor...

Page 10: ...long term accuracy it is advisable to activate synchronisation on 50 60 Hz mains with frequency adjustment Instead of its STANDARD function the output of channel 1 is switched on and off cyclically Th...

Page 11: ...iami New York 75 W 40 N San Francisco 122 W 38 N 116 E 40 N Chongqing 107 E 30 N Harbin 127 E 46 N Hong Kong 114 E 22 N Shenyang 123 E 42 N 104 E 36 N Xi an 109 E 34 N Manila 73 E 34 N Kabul 5 00 3 30...

Reviews: