background image

The Pass and Seymour Combination Switch/ GFCI (catalog number

1595SWT and 15952SWT) are devices that offer several installation

options. Before attempting the installation the installer must first review

and select the option from below that suits his or her needs.

When installing catalog numbers 1595SWT and 15952SWT, in some

applications there will be six or more conductors in the box. The

National Electric Code may require more volume than a single box

offers when there are six or more #14 or #12 AWG wires in the box.

A larger box or box extension may be required to comply with the

National Electric Code.

BEFORE ATTEMPTING INSTALLATION

of switch(es) install GFCI

according to the enclosed sheet titled “Installing and Testing a GFCI

Receptacle”. Adhere to all cautions and warnings on that instruction

sheet.

Wiring Option 1

– Switch (catalog no.1595SWT) or switches (catalog no.15952SWT)

function as independent single pole switches

without GFCI

protection for either the switch or the switched load.

– GFCI protection is provided to it’s own receptacle openings and to

receptacles properly wired downstream from the load side of the

GFCI (optional).

NOTE:

If you are replacing a combination device and it was split-wired

(switch half was powered from one circuit breaker and the receptacle

half was powered from another) then refer to

wiring diagram

A1

or

A2

below. If you are replacing a combination device and it was wired such

that the switch half and the receptacle half were both powered from the

same circuit breaker, then refer to

wiring diagram

B1

or

B2

below.

Wiring Option 2

– Switch (catalog no.1595SWT) or switches (catalog no.15952SWT)

function as independent single pole switches

with GFCI protection

provided to the switch and the switched load.

– GFCI protection is provided to it’s own receptacle openings and to

receptacles properly wired downstream from the load side of the

GFCI (optional).

NOTE:

If you are replacing a combination device and it was split-wired

(switch half was powered from one circuit breaker and the receptacle

half was powered from another) then you will not be using the hot

circuit conductor which supplied power to the switch on the old

combination device. Terminate and properly insulate this conductor,

then proceed to wire according to

wiring diagram

C1

or

C2

below.

SWITCH INSTALLATION INSTRUCTIONS FOR:

COMBINATION SWITCH/GFCI OUTLET

Catalog Nos. 1595SWT and 15952SWT

P.O. Box 4822, Syracuse, NY 13221-4822 • www.passandseymour.com • (800-223-4185)

P/N 340737 Rev. C

LOAD CABLE BRINGS POWER TO OTHER RECEPTACLES (OPTIONAL)

SWITCHED LOAD

GROUND

GROUND

CONNECTION

TO BOX

LINE CABLE

BRINGS POWER

TO THE SWITCH

FROM CIRCUIT

BREAKER #2

ELECTRICAL

BOX

LINE CABLE BRINGS

POWER TO THE GFCI FROM

CIRCUIT BREAKER #1

WHITE

BLACK

SWITCH

LEAD

BLACK

SWITCH

LEAD

GROUND

HOT

BLACK

LINE

LOAD

W

HI

TE

HO

T

W

HI

TE

HO

T

Wiring Diagram A1

(Single Switch Cat. #1595SWT)

LINE CABLE BRINGS

POWER TO THE GFCI FROM

CIRCUIT BREAKER #1

LOAD CABLE BRINGS POWER TO OTHER RECEPTACLES (OPTIONAL)

GROUND

GROUND

CONNECTION

TO BOX

LINE CABLE

BRINGS POWER

TO THE SWITCH(ES)

FROM CIRCUIT

BREAKER #2

ELECTRICAL

BOX

WHITE

YELLOW

SWITCH

LEAD

BLACK

COMMON

SWITCH

LEAD

GROUND

HOT

BLACK

RED

SWITCH

LEAD

HOT

LIGHT

HOT

FAN

SWITCHED LOADS

FAN

LIGHT

LINE

LOAD

W

H

IT

E

H

O

T

W

H

IT

E

H

O

T

Wiring Diagram A2

(Double Switch Cat. #15952SWT)

LOAD CABLE BRINGS POWER TO OTHER RECEPTACLES (OPTIONAL)

SWITCHED LOAD

GROUND

GROUND

CONNECTION

TO BOX

LINE CABLE

BRINGS POWER

TO THE GFCI

AND SWITCH

ELECTRICAL

BOX

WHITE

BLACK

SWITCH

LEAD

BLACK

SWITCH

LEAD

BLACK

LINE

LOAD

W

HI

TE

HO

T

W

HI

TE

HO

T

Wiring Diagram B1

(Single Switch Cat. #1595SWT)

LOAD CABLE BRINGS POWER TO OTHER RECEPTACLES (OPTIONAL)

SWITCHED LOAD

GROUND

GROUND

CONNECTION

TO BOX

LINE CABLE

BRINGS POWER

TO THE GFCI

ELECTRICAL

BOX

WHITE

BLACK

SWITCH

LEAD

BLACK

SWITCH

LEAD

BLACK

LINE

LOAD

W

HI

TE

HO

T

W

HI

TE

HO

T

Wiring Diagram C1

(Single Switch Cat. #1595SWT)

LOAD CABLE BRINGS POWER TO OTHER RECEPTACLES (OPTIONAL)

GROUND

GROUND

CONNECTION

TO BOX

LINE CABLE

BRINGS POWER

TO THE GFCI

AND SWITCHES

ELECTRICAL

BOX

BLACK

COMMON

SWITCH

LEAD

YELLOW

SWITCH LEAD

RED

SWITCH LEAD

LIGHT

FAN

SWITCHED LOADS

FAN

LIGHT

LINE

LOAD

W

H

IT

E

H

O

T

W

H

IT

E

H

O

T

FAN LEAD

LIGHT LEAD

WHITE

Wiring Diagram B2

(Double Switch Cat. #15952SWT)

LOAD CABLE BRINGS POWER TO OTHER RECEPTACLES (OPTIONAL)

GROUND

GROUND

CONNECTION

TO BOX

LINE CABLE

BRINGS POWER

TO THE GFCI

ELECTRICAL

BOX

WHITE

YELLOW

SWITCH LEAD

BLACK

BLACK

COMMON

SWITCH LEAD

RED

SWITCH LEAD

SWITCHED LOADS

FAN

LIGHT

LINE

LOAD

W

H

IT

E

H

O

T

W

H

IT

E

H

O

T

FAN LEAD

LIGHT LEAD

Wiring Diagram C2

(Double Switch Cat. #15952SWT)

 

http://waterheatertimer.org/How-to-wire-GFCI.html

  