UNIT DESCRIPTION

The LightSense™ Wireless devices use radio signals to communicate with each

other to control lighting and other types of electric loads in selected areas.

LightSense wireless devices use the 900MHz band for high-speed control

communication. Using the patented “frequency-agile” Top Dog™ technology,

LightSense wireless devices avoid interference with other 900MHz devices,

such as cordless phones and baby monitors.

Load Types

Use the PSWDI incandescent dimmer for these load types (60-600W at 120V):
• Incandescent & quartz halogen lamps

Do not mix different load types

on the same dimmer.

Do not use with diode equipped

(some types of energy saving) lamps.

Do not use for motors

.

For dimmable, 2-wire fluorescent and compact fluorescent fixtures, electronic

low voltage, neon or cold cathode fixtures or diode equipped lamps, use the

LightSense PSWDU wireless universal dimmer, or the LightSense PSHDU

universal dimmer.

Derating

When

more than one dimmer is installed in a multi-gang box, it is necessary to

reduce the maximum load on each dimmer.
• For a dimmer in either end position of a multi-gang box, reduce its maximum

load to 500W.

• For a dimmer in a central position of a multi-gang box, reduce its maximum

load to 400W.

Call 800.223.4185 for Technical Support

CAUTION

To reduce the risk of

overheating and possible

damage to other equipment, do

not install to control a receptacle,

a motor-operated appliance, or a

fluorescent lighting fixture.

CAUTION

Afin de réduire le risque de

surchauffe et la possibilité

d’endommager d’autres matériels,

ne pas installer pour commander

une prise, un appareil à moteur,

ou une lampe fluorescente.

Summary of Contents for Pass & Seymour LightSense PSWDI

Page 1: ...erating Voltage 120VAC 60Hz Maximum Load Rating 600W Minimum Load Required 60W Load Type Compatibility 60 600W Incandescent tungsten quartz halogen transformers U S Patent 6 175 220 Other utility desi...

Page 2: ...and compact fluorescent fixtures electronic low voltage neon or cold cathode fixtures or diode equipped lamps use the LightSense PSWDU wireless universal dimmer or the LightSense PSHDU universal dimm...

Page 3: ...LOAD and GND supply wires to the correspondingly marked screw terminals according to one of the wiring diagrams below 5 If NEUTRAL wires are provided to the fixture connect them together using a wire...

Page 4: ...2 seconds All device LEDs in the house change to solid green indicating house binding is complete Adding a Device to an Existing Installation If you re adding or replacing a device in a LightSense wir...

Page 5: ...to normal operation press The status LED lights Power Fail Memory After a power failure all LightSense devices automatically return to the state that they were in immediately prior to loss of power Al...

Page 6: ...flashing LED Included in the Group Green flashing LED NOT included in the Group If you get to a device and it is NOT flashing the 5 minute binding process timer may have expired Go back to step 1 and...

Page 7: ...uration mistake I need to start over You can reset any LightSense wireless device to factory default settings by pressing and holding until the LED changes to solid yellow approximately 10 seconds Dur...

Page 8: ...instructions concerning return or repair 2 return the product to Pass Seymour postage paid with your name and address and a written description of the installation or use of the Pass Seymour product...