background image

SET HOUSE ID

All LightSense™ wireless devices installed in the same home must acquire the

same unique House ID before use. This process is known as house binding.

Each LightSense wireless device is bound to all other LightSense wireless

devices in the house.

New Installation

1. With all devices installed and energized, make sure that every LightSense

wireless device LED is yellow. If

any LED is off, be sure the circuit

breaker is on and the device is

correctly installed.

2. Press

on any device paddle

until the LED flashes yellow

(about 2 seconds). This indicates

that it has acquired a unique

House ID.

3. Make sure that all other LightSense wireless device LEDs are flashing

green, indicating that they have acquired the same House ID.

4. Return to the device used in step 2, which is still flashing yellow. Press

until the LED changes to solid green (about 2 seconds). All device LEDs in

the house change to solid green, indicating house binding is complete.

Adding a Device to an Existing Installation

If you’re adding or replacing a device in a LightSense wireless installation that is

already operating, the new device must acquire the same House ID as the other

LightSense wireless devices in the house. After the new device is powered up,

the LED should be solid yellow. This indicates that it has not yet acquired a

House ID. To acquire the House ID for the existing system:
1. Press

on any

previously bound

device until the LED flashes yellow

(about 2 seconds).

2. Verify that the newly added device LED is flashing green, indicating that it

has acquired the House ID.

3. Return to the

same previously bound

device used in step 1 and press

until the LED changes to solid green (about 2 seconds). All device LEDs

should now be solid green.

Call 800.223.4185 for Technical Support

When you see

in the instructions,

firmly press and

hold both the top

and bottom of the

device paddle until

the LED changes

(about 2 seconds).

Summary of Contents for Pass & Seymour LightSense PSWDI

Page 1: ...erating Voltage 120VAC 60Hz Maximum Load Rating 600W Minimum Load Required 60W Load Type Compatibility 60 600W Incandescent tungsten quartz halogen transformers U S Patent 6 175 220 Other utility desi...

Page 2: ...and compact fluorescent fixtures electronic low voltage neon or cold cathode fixtures or diode equipped lamps use the LightSense PSWDU wireless universal dimmer or the LightSense PSHDU universal dimm...

Page 3: ...LOAD and GND supply wires to the correspondingly marked screw terminals according to one of the wiring diagrams below 5 If NEUTRAL wires are provided to the fixture connect them together using a wire...

Page 4: ...2 seconds All device LEDs in the house change to solid green indicating house binding is complete Adding a Device to an Existing Installation If you re adding or replacing a device in a LightSense wir...

Page 5: ...to normal operation press The status LED lights Power Fail Memory After a power failure all LightSense devices automatically return to the state that they were in immediately prior to loss of power Al...

Page 6: ...flashing LED Included in the Group Green flashing LED NOT included in the Group If you get to a device and it is NOT flashing the 5 minute binding process timer may have expired Go back to step 1 and...

Page 7: ...uration mistake I need to start over You can reset any LightSense wireless device to factory default settings by pressing and holding until the LED changes to solid yellow approximately 10 seconds Dur...

Page 8: ...instructions concerning return or repair 2 return the product to Pass Seymour postage paid with your name and address and a written description of the installation or use of the Pass Seymour product...