background image

LIMITED FIVE YEAR WARRANTY

Pass & Seymour will remedy any defect in workmanship or material in Pass & Seymour

products which may develop under proper and normal use within five years from date of

purchase by a consumer: (1) by repair or replacement, or, at Pass & Seymour’s option, (2)

by return of an amount equal to consumer’s purchase price. Such remedy is IN LIEU OF

ANY AND ALL EXPRESSED OR IMPLIED WARRANTIES OF MERCHANTABILITY OR

FITNESS FOR A PARTICULAR PURPOSE. Such remedy by Pass & Seymour does not

include or cover cost of labor for removal or reinstallation of the product. ALL OTHER

FURTHER ELEMENTS OF DAMAGE (INCIDENTAL OR CONSEQUENTIAL DAMAGES)

FOR BREACH OF ANY AND ALL EXPRESSED OR IMPLIED WARRANTIES INCLUDING

WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE

ARE EXCLUDED HEREBY. (Some states do not allow disclaimers or exclusion or limita-

tion of incidental or consequential damages, so the above disclaimer and limitation or

exclusion may not apply to you.) ANY IMPLIED WARRANTIES INCLUDING WHERE

REQUIRED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR

PURPOSE SHALL BE LIMITED TO THE FIVE YEAR PERIOD SET FORTH ABOVE.

(Some states do not allow limitations on how long an implied warranty lasts, so the above

limitation may not apply to you.) To ensure safety, all repairs to Pass & Seymour products

must be made by Pass & Seymour, or under its specific direction. Procedure to obtain per-

formance of any warranty obligation is as follows: (1) Contact Pass & Seymour, Syracuse,

New York 13221, for instructions concerning return or repair; (2) return the product to Pass

& Seymour, postage paid, with your name and address and a written description of the

installation or use of the Pass & Seymour product, and the observed defects or failure to

operate, or other claimed basis for dissatisfaction. This warranty gives you specific legal

rights and you may also have other rights which vary from state to state.

FCC NOTICE

This equipment has been tested and found to comply with the limits for a Class

B digital device, pursuant to part 15 of the FCC Rules. These limits are

designed to provide reasonable protection against harmful interference in a

residential installation. This equipment generates, uses and can radiate radio

frequency energy and, if not installed and used in accordance with the

instructions, may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular

installation. If this equipment does cause harmful interference to radio or

television reception, which can be determined by turning the equipment off and

on, the user is encouraged to try to correct the interference by one or more of

the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which

the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications to this device not explicitly approved by

Pass & Seymour/Legrand could void your authority to operate this equipment.

P.O. Box 4822 • Syracuse, NY • 13221-4822

Technical Support: 800.223.4185

www.passandseymour.com

Summary of Contents for Pass & Seymour LightSense PSWDI

Page 1: ...erating Voltage 120VAC 60Hz Maximum Load Rating 600W Minimum Load Required 60W Load Type Compatibility 60 600W Incandescent tungsten quartz halogen transformers U S Patent 6 175 220 Other utility desi...

Page 2: ...and compact fluorescent fixtures electronic low voltage neon or cold cathode fixtures or diode equipped lamps use the LightSense PSWDU wireless universal dimmer or the LightSense PSHDU universal dimm...

Page 3: ...LOAD and GND supply wires to the correspondingly marked screw terminals according to one of the wiring diagrams below 5 If NEUTRAL wires are provided to the fixture connect them together using a wire...

Page 4: ...2 seconds All device LEDs in the house change to solid green indicating house binding is complete Adding a Device to an Existing Installation If you re adding or replacing a device in a LightSense wir...

Page 5: ...to normal operation press The status LED lights Power Fail Memory After a power failure all LightSense devices automatically return to the state that they were in immediately prior to loss of power Al...

Page 6: ...flashing LED Included in the Group Green flashing LED NOT included in the Group If you get to a device and it is NOT flashing the 5 minute binding process timer may have expired Go back to step 1 and...

Page 7: ...uration mistake I need to start over You can reset any LightSense wireless device to factory default settings by pressing and holding until the LED changes to solid yellow approximately 10 seconds Dur...

Page 8: ...instructions concerning return or repair 2 return the product to Pass Seymour postage paid with your name and address and a written description of the installation or use of the Pass Seymour product...