Chapter 6: Using the PX3TS
134
▪
When showing a numeric sensor's reading, the appropriate
measurement unit is displayed to the right of the reading.
Measurement
units
Sensor types
%
A relative humidity sensor
A temperature sensor
m/s
An air flow sensor
Pa
An air pressure sensor
NO measurement
units
For an "absolute" humidity sensor, the measurement
unit is g/m
3
, which cannot be displayed on the LCD.
▪
Available states for a state sensor:
States
Description
nor
Normal state.
ALA
Alarmed state.
▪
This state is accompanied with the word "ALARM" below
it.
▪
Available states for a dry contact signal actuator (DX sensor series):
States
Description
On
The actuator is turned on.
Off
The actuator is turned off.
Note: Numeric sensors show both numeric readings and sensor states to
indicate environmental or internal conditions while state sensors show
sensor states only to indicate state changes.
5.
Press the FUNC button to show the sensor's port position. There are two
types of information.
▪
P:n
(where n is the SENSOR port's number): This information indicates
the SENSOR port number.
▪
C:x
(where x is the sensor's position in a sensor chain): This information
indicates the sensor's position in a chain, which is available for DPX2,
DPX3 and DX sensors only. The LCD display will cycle between the port
information (
P:n
) and chain position information (
C:x
).
Note that if the DPX3-ENVHUB4 sensor hub is used to connect the
DPX2, DPX3 or DX sensors, the chain position information (C:x) is
displayed twice - the first one indicates the sensor hub's chain position,
which is always
C:1
, and the second one indicates the sensor's chain
position.
Summary of Contents for Raritan PX3TS
Page 4: ......
Page 6: ......
Page 20: ......
Page 80: ...Chapter 4 Connecting External Equipment Optional 60...
Page 109: ...Chapter 5 PDU Linking 89...
Page 117: ...Chapter 5 PDU Linking 97...
Page 441: ...Chapter 7 Using the Web Interface 421...
Page 464: ...Chapter 7 Using the Web Interface 444...
Page 465: ...Chapter 7 Using the Web Interface 445 Continued...
Page 746: ...Appendix A Specifications 726...
Page 823: ...Appendix I RADIUS Configuration Illustration 803 Note If your PX3TS uses PAP then select PAP...
Page 828: ...Appendix I RADIUS Configuration Illustration 808 14 The new attribute is added Click OK...
Page 829: ...Appendix I RADIUS Configuration Illustration 809 15 Click Next to continue...
Page 860: ...Appendix J Additional PX3TS Information 840...
Page 890: ...Appendix K Integration 870 3 Click OK...
Page 900: ......