Using the PRO3X Command Line Interface (CLI)
PRO3X User Guide
–
Command Line Interface (CLI)
26 of 182
Overcurrent Protector Sensor Threshold Information
This command is only available for models with overcurrent protectors for protecting outlets.
This command syntax shows the specified overcurrent protector sensor's threshold-related information.
#
show sensor ocp <n> <sensor type>
To show detailed information, add the parameter "details" to the end of the command.
#
show sensor ocp <n> <sensor type>
details
Variables:
<n> is the number of the overcurrent protector whose sensors you want to query.
<sensor type> is one of the following sensor types:
Sensor type
Description
current
Current sensor
Displayed information:
Without the parameter
details
only the reading, state, threshold, de-assertion hysteresis and assertion timeout settings of
the specified overcurrent protector sensor are displayed.
With the parameter
details
more sensor information is displayed, including resolution and range.
Summary of Contents for Server Technology PRO3X