background image

DESCRIPTION AND OPERATION

The RS-100BA Vacancy Sensor is designed to replace a standard light switch. It
is ideal for bedroom and bathroom applications. 

Like a standard switch, you press the ON/OFF button to turn the light ON and
OFF. Unlike a standard switch, the RS-100BA automatically turns OFF the light
after the coverage area has been vacant for 30 minutes. If motion is detected
within 30 seconds after it automatically turns OFF, the RS-100BA automatically
turns the light back ON.

Pilot Light

To help you locate the RS-100BA in a dark room, the pilot light illuminates the
ON/OFF button while the controlled light is OFF. When the controlled light is
ON, the pilot light is OFF.

Coverage Area 

The RS-100BA has a maximum coverage range of 180 degrees and a coverage
area of 600 square feet (56 square meters). The sensor must have a clear and
unobstructed view of the coverage area. Objects blocking the sensor’s lens may
prevent detection thereby causing the light to turn off even though someone is
in the area. 

Windows, glass doors, and other transparent

barriers will obstruct the sensor’s view

and prevent detection. 

25'

(7.6m)

12'

(3.7m)

Call 888.817.0571 for Technical Support

Fig 1:  Sensor Coverage Area

RS-100BA

Vacancy Sensor Switch

with Manual ON/OFF   

Ins

tallation Ins

tructions

SPECIFICATIONS

Voltage

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120VAC, 60Hz

Load 

Single Pole Circuit  . . . . 25– 500 Watt Incandescent light

Time Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 minutes
Environment  . . . . . . . . . . . . . . . . .Residential Indoor use only

Operating Temperature  . . . . . . . .32° to 131°F (0° to 55°C)
Humidity . . . . . . . . . . . . . . . . . . . .95% RH, non-condensing

Electrical Supply Wire  . . Minimum temp. rating 75°C (167°F)
Tools Needed

Insulated Screwdriver
Wire Strippers

Santa Clara, CA 95050