DESCRIPTION AND OPERATION
The RS-100BA Vacancy Sensor is designed to replace a standard light switch. It
is ideal for bedroom and bathroom applications.
Like a standard switch, you press the ON/OFF button to turn the light ON and
OFF. Unlike a standard switch, the RS-100BA automatically turns OFF the light
after the coverage area has been vacant for 30 minutes. If motion is detected
within 30 seconds after it automatically turns OFF, the RS-100BA automatically
turns the light back ON.
Pilot Light
To help you locate the RS-100BA in a dark room, the pilot light illuminates the
ON/OFF button while the controlled light is OFF. When the controlled light is
ON, the pilot light is OFF.
Coverage Area
The RS-100BA has a maximum coverage range of 180 degrees and a coverage
area of 600 square feet (56 square meters). The sensor must have a clear and
unobstructed view of the coverage area. Objects blocking the sensor’s lens may
prevent detection thereby causing the light to turn off even though someone is
in the area.
Windows, glass doors, and other transparent
barriers will obstruct the sensor’s view
and prevent detection.
25'
(7.6m)
12'
(3.7m)
Call 888.817.0571 for Technical Support
Fig 1: Sensor Coverage Area
RS-100BA
Vacancy Sensor Switch
with Manual ON/OFF
Ins
tallation Ins
tructions
SPECIFICATIONS
Voltage
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120VAC, 60Hz
Load
Single Pole Circuit . . . . 25– 500 Watt Incandescent light
Time Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 minutes
Environment . . . . . . . . . . . . . . . . .Residential Indoor use only
Operating Temperature . . . . . . . .32° to 131°F (0° to 55°C)
Humidity . . . . . . . . . . . . . . . . . . . .95% RH, non-condensing
Electrical Supply Wire . . Minimum temp. rating 75°C (167°F)
Tools Needed
Insulated Screwdriver
Wire Strippers
Santa Clara, CA 95050
Lens
ON/OFF button
with pilot light
Please read all instructions before installing