DESCRIPTION AND OPERATION

The RS-100U Application-Specifi c Wall Switch Occupancy Sensor is designed 
to replace a residential light switch. It is ideal for laundry rooms, utility rooms, 
storage areas, closets and any other indoor area in a residential building where 
occupancy sensor-based automatic ON/OFF controls are desirable. The sensor 
requires no adjustments to operate successfully in those particular applications 
for which it was designed.

Lighted Switch

To help you locate the RS-100U in a dark room, an amber LED illuminates the 
ON/OFF button while the controlled light (load) is OFF. When the load is ON, the 
LED is OFF.

Push Button

The push button can be used to manually turn ON and OFF the load. To turn the 
load OFF, tap fi rmly on the push button once. The lighted switch will turn ON 
and the load will turn OFF. If the load is turned OFF manually, Automatic-ON is 
reenabled when no motion is detected for 5 minutes.

Time Delay

The RS-100U has a fi xed time delay of 5 minutes. Lights will remain ON for 5 
minutes after the last motion detection.

Coverage Area

The RS-100U has a maximum range of 180 
degrees and a coverage area of 600 sq. feet (56 
sq, meters). The sensor must have a clear and 
unobstructed view of the coverage area. Objects 
blocking the sensor’s lens may prevent detection 
thereby causing the light to turn OFF even though 
someone is in the area.

Windows, glass doors, and other transparent barriers will 

obstruct the sensor’s view and prevent detection.

RS-100U

PIR Application-Specifi c 

Wall Switch 

Occupancy Sensor

with Manual ON/OFF   

Lens

Lighted Switch
ON/OFF Button

SPECIFICATIONS

Voltage ............................................................... 120VAC, 60Hz
Load (Single Pole Circuit)
 

Incandescent ..................................................  25-500 Watts

Time Delay  ................................................................ 5 minutes
Environment ..................................Residential Indoor use only
 

Operating Temperature ............... 32° to 131°F (0° to 55°C)

 

Humidity ...................................... 95% RH, non-condensing

Electrical Supply Wire ..... minimum temp rating 167° F (75°C)
Tools Needed
 Insulated 

Screwdriver

 Wire 

Strippers

Santa Clara, CA 95050

25'

(7.6m)

12'

(3.7m)

Fig. 1: Sensor Coverage Area

Call 888.817.0571 for Technical Support