DESCRIPTION AND OPERATION

The RS-250 Universal Application Wall Switch Vacancy Sensor is designed to 
replace a standard light or fan switch. It is ideal for living and dining rooms, family 
rooms, bedrooms, bathrooms and any other indoor area in a residential space 
where occupancy sensor-based manual ON/OFF controls are desirable. 

Like a standard switch, you press the ON/OFF button to turn the light or fan 
(controlled load) ON and OFF. Unlike a standard switch, the RS-250 automatically 
turns OFF the controlled load after the coverage area has been vacant for a period 
of time (Time Delay). If motion is detected within 30 seconds after it automatically 
turns OFF, the RS-250 automatically turns the load back ON.

While the sensor is factory preset as a Vacancy Sensor with manual ON operation, 
it can be adjusted to work as an Occupancy Sensor that turns the controlled load 
ON automatically upon detection of occupancy in the area.

Lighted Switch

To help you locate the RS-250 in a dark room, the amber LED illuminates the 
ON/OFF button while the controlled load is OFF. When the controlled load is ON, 
the LED is OFF.

Operating Modes

There are two operating modes to select from during set up:

MODE 1

 

Vacancy sensor (Manual-ON/OFF, Auto-OFF): The user must press 

the ON/OFF button to turn the load ON. The RS-250 keeps the load ON until no 
motion is detected for the selected time delay period (adjustable from 15 seconds 
to 30 minutes). There is a 30 second reset delay. If motion is detected during this 
time, the sensor turns the load back on automatically. After the reset delay time 
has elapsed, the ON/OFF button must be pressed to turn ON the load.

MODE 2

 

Occupancy sensor (Auto-ON/OFF with manual control and reset 

to auto after 5 minutes of vacancy): The load turns ON and OFF automatically 
based on occupancy detection. The RS-250 keeps the load ON until no motion is 
detected for the selected time delay period. If the load is turned OFF manually, 
automatic-ON is re-enabled when no motion is detected for 5 minutes. This 
prevents the load from being turned ON after it was deliberately turned OFF.

RS-250

Universal Application Wall Switch

 Vacancy Sensor

with Manual ON/OFF   

Lens

Lighted Switch 
ON/OFF button 

SPECIFICATIONS

Voltage ............................................................... 120VAC, 60Hz
Load (Single Pole Circuit)
 

Incandescent or fl uorescent ............................ 0-600 Watts

 

Fan motor ..................................................................  1/6 hp

Time Delay Adjustment .................... 15 seconds to 30 minutes
Light Level Adjustment ....................................... 10 fc to 150 fc
Environment ..................................Residential Indoor use only
 

Operating Temperature ............... 32° to 131°F (0° to 55°C)

 

Humidity ...................................... 95% RH, non-condensing

Tools Needed
 Insulated 

Screwdriver

 Wire 

Strippers

Santa Clara, CA 95050

Call 888.817.0571 for Technical Support

Summary of Contents for Watt Stopper RS-250

Page 1: ...ing set up MODE 1 Vacancy sensor Manual ON OFF Auto OFF The user must press the ON OFF button to turn the load ON The RS 250 keeps the load ON until no motion is detected for the selected time delay p...

Page 2: ...e the switch box After the power is turned OFF at the circuit breaker box remove the existing wall plate and mounting screws Pull the old switch out from the wall box 2 Identify the type of circuit In...

Page 3: ...he button downward approximately 1 2 inch to expose the mode button and adjustment trimpots Setting up the Operating Mode Select the operating mode by pressing the Mode button The amber LED behind the...

Page 4: ...load turns OFF after 5 seconds if no motion is detected 3 Move into the coverage area The controlled load turns ON for 5 seconds each time the sensor detects motion After 5 seconds expire without moti...

Page 5: ...on the part of Watt Stopper Legrand for consequential damages arising out of or in connection with the use or performance of this product or other indirect damages with respect to loss of property rev...

Page 6: ...l bot n de ENCENDIDO APAGADO cuando la carga controlada se encuentra apagada Cuando por el contrario esta ltima se encuentra encendida el LED estar apagado Modos de Operaci n Es posible elegir entre d...

Page 7: ...e exista detecci n INSTALACION Y CABLEADO ADVERTENICA Desconecte la corriente que alimenta la caja de conexiones apagando el disyuntor breaker o removiendo el fusible para el circuito correspondiente...

Page 8: ...emente por ambos extremos y j lela hacia afuera delicadamente No trate de despegarla completamente del sensor 2 Tome rmemente el bot n de ENCENDIDO APAGADO por ambos extremos y desl celo hacia abajo a...

Page 9: ...asta que las luces se enciendan A este valor de ajuste las luces no se encender n autom ticamente con la detecci n de ocupaci n si la cantidad de luz natural es mayor a la existente actualmente 6 Reaj...

Page 10: ...apaga autom ticamente Presione el bot n de ENCENDIDO APAGADO Si la carga se apaga prosiga con el siguiente paso El tiempo del retardo de apagado puede ser con gurado desde 30 segundos hasta 30 minutos...

Reviews: