         WWW.LEGRAND.US/WATTSTOPPER - IS-00709-F  Commercial Enclosure Solutions — MODEL: LCAP44A & LCA Main Lug 

page 5 of 8 

LCA P4 4-36 PA NEL

SURFACE MOUNT BOX

4-1/ 2”  DEEP

W ITH DOORS INSTA LLED

77”

19

5.

58
c

m

44.

7

5

” (
11

3

.6

65
c

m
)

32
.2

5”
 (

8

1.9

15cm

)

4 .5”   ( 11.4 3cm )

24 .0 ”  ( 60 .9 6 cm )

LCA P4 4-36 PA NEL

MA IN LUGS

W ITH  DOORS  &

DEA DFRONT REMOVED

BA RRIER

COMMUNICATION
CONDUIT

GROUND
BA R

CIRCUIT
BREA KERS

NEUTRA L

BA R

DIMMER

SECTION

BREA KER

SECTION

BUS DIAGRA MS

225A  MA IN LUGS

20
20
20

20

20

20

20

20

20

20

20

20

20

20

20

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

29

27

25

23

21

20

30

28

26

24

22

32

31

33
35

34
36

20
20
20

20

20

20

20

20

20

20

20

20

20

20

20

20
20

15

20
20
20

G

N

D
B

U

S

NE

U

T

R

A

L

20 8 Y/ 120 V 30  4 W

( 10 KA IC-22 KA IC-65 KA IC)

4 80 Y/ 277V 30  4 W

(14 KA IC)

20
20
20

20

20

20

20

20

20

20

20

20

20

20

20

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

29

27

25

23

21

20

30

28

26

24

22

32

31

33
35

34
36

20
20
20

20

20

20

20

20

20

20

20

20

20

20

20

20
20

15

20
20
20

G

N

D
B

U

S

NE

U

T

R

A

L

120 V/ 24 0 V 10  3W

(10 KA IC-22 KA IC-65 KA IC)

LCAP44ALO/MLO (36 Breakers) 

1.

 

Enclosure upper section for LCAP44ALO Panel. 

2.

 

Enclosure lower section for up to 36 breakers. Select 

the 

Main Lug

 option 

MLO

 option for (up to) 36, 20A  

breakers. 

3.

 

Breaker section may be configured for 4-wire or 3-wire 

power configurations. 

(See last page for breaker/order options) 

LCA P4 4-18 PA NEL

SURFACE MOUNT

BOX 4 -1/ 2”  DEEP W ITH

DOORS INSTA LLED

77

19

5

.58c

m

4

4

.7

5

” (

113
.6

6

5

c

m
)

3

2

.2

5”
 (

8

1.9

15cm

)

4 .5”  ( 11.4 3cm )

24 .0 ”   ( 60 .9 6 cm )

LCA P4 4-18 PA NEL

MA IN BREA KER

W ITH DOORS &

DEA DFRONT REMOVED

BA RRIER

COMMUNICATION
CONDUIT

GROUND
BA R

CIRCUIT
BREA KERS

NEUTRA L

BA R

BUS DI A GRA MS

10 0 A  MA IN BREA KER

3P

10 0 A
10 0 A

MA IN

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

20
20

20
20
20

15

20

20

20

20

20

20
20
20
20
20
20

NE

U

T

R

A

L

G

N

D
B

U

S

BKR.

20

2P

10 0 A
10 0 A

MA IN

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

20
20

20
20
20

15

20

20

20

20

20

20
20
20
20
20
20

NE

U

T

R

A

L

G

N

D
B

U

S

BKR.

20

20 8Y/ 120 V 30  4 W

( 10 KA IC-22KA IC-65KA IC)

4 80Y/ 277V 30  4 W

( 14KA IC-*35KA IC-*65KA IC)

*SERIES RATED

120 V/ 24 0 V 10  3W

( 10 KA IC-22KA IC-65KA IC)

DIMMER

SECTION

LCAP44ALO/MCB 

1.

 

Enclosure upper section for 
LCAP44ALO Panel. 

2.

 

Enclosure lower section for up to 18 
breakers. Select the 

Main Lug

 type 

and change to 

MCB

 to add a Main 

Breaker option. 

3.

 

Breaker section may be configured 

for 4-wire or 3-wire power 
configurations. 

(See last page for breaker/order options) 

LCAP44ALO/MCB with Main Lug & Main Breaker Enclosure Multi-View

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 
LCAP44ALO/MLO with Main Lug (up to 36 breakers) Enclosure Multi-View

 

 

Summary of Contents for Wattstopper LCAP Series

Page 1: ...ries Enclosure Facts Enclosures must be populated from left to right and top down o Blank positions cannot be left between lighting modules in Design Center setup Enclosures are pre configured and wir...

Page 2: ...M P 1 with 5 pre wired blocks optional 1 COM POE SWITCH Ethernet sw 1 to 5 VA RRU 1 120V or VA RRU 1 277V LCAP44A 6 KIT included 1 LCAP44A panel 6 LVOS 0 10 PWM P 1 with 6 pre wired blocks optional 1...

Page 3: ...ug Panel options range from 18 to 36 circuits 208 480V and 10kAIC to 65kAIC and may be configured with a main breaker option Setup In Design Center Understanding LCAP and Main Lug panels LCAP panels w...

Page 4: ...44ALO Panel 2 Enclosure lower section for up to 18 breakers Select the Main Lug option MLO option for up to 18 20A breakers 3 Breaker section may be configured for 4 wire or 3 wire power configuration...

Page 5: ...ain Lug option MLO option for up to 36 20A breakers 3 Breaker section may be configured for 4 wire or 3 wire power configurations See last page for breaker order options LCAP44 1 8 PANEL SURFACE MOUNT...

Page 6: ...umber Ordering Key Design Center will generate LCAP44ALO MLO MCB part numbers automatically as the enclosures are built This key is for help in understanding and creating orders in the LCAP Quote Tool...

Page 7: ...WWW LEGRAND US WATTSTOPPER IS 00709 F Commercial Enclosure Solutions MODEL LCAP44A LCAP44ALO Main Lug page 7 of 8...

Page 8: ...WWW LEGRAND US WATTSTOPPER IS 00709 F Commercial Enclosure Solutions MODEL LCAP44A LCAP44ALO Main Lug page 8 of 8...

Reviews: