Wattstopper
®
Digital Lighting Management Low Voltage Switches (v3)
Interrupteurs basse tension de gestion numérique de l’éclairage (v3)
Interruptores de bajo voltaje de control de iluminación digital (v3)
Quick Start Guide • Guide de démarrage rapide • Guía de inicio rápido
No: 23271 – 07/16 rev. 1
Catalog Numbers • Les Numéros de Catalogue • Los Números de Catálogo:
LMSW-101, LMSW-102, LMSW-103, LMSW-104, LMSW-108
Country of Origin: Made in China • Pays d’origine: Fabriqué en Chine • País de origen: Hecho en China
Models ending in -U are BAA and TAA compliant (Product produced in the U.S.)
This unit is pre-set for Plug n’ Go™ operation, adjustment is optional.
For full operational details, adjustment and more features of the product, see the
DLM System Installation Guide provided with Wattstopper room controllers, and
also available at www.legrand.us/wattstopper.
Installation shall be in accordance with all applicable regulations, local and
NEC codes.
Wire connections shall be rated suitable for the wire size (lead and
building wiring) employed.
For Class 2 DLM devices and device wiring: To be connected to a Class 2 power
source only. Do not reclassify and install as Class 1, or Power and Lighting
Wiring.
Do not apply cleaning solvent directly onto unit. Apply cleaning solvent onto a
cloth, then wipe the unit to clean it.
LMSW-108
LMSW-104
LMSW-103
LMSW-102
LMSW-101
MOUNTING THE SWITCH
BUTTONS AND INDICATORS
Red configuration LED
Blue load status LED(s)
On/Off button(s)
Configuration button
(behind switch plate)
CAUTION:
TO CONNECT A COMPUTER TO THE DLM LOCAL
NETWORK USE THE LMCI-100.
NEVER CONNECT THE DLM
LOCAL NETWORK TO AN ETHERNET PORT
– IT MAY
DAMAGE COMPUTERS AND OTHER CONNECTED EQUIPMENT.
WARNING:
Do not install to cover a junction box having Class
1, 3 or Power and Lighting Circuits.
SPECIFICATIONS
Voltage .............................................................................. 24VDC
Current Consumption .............................................................5mA
Power Supply ................................. Wattstopper Room Controller
Connection to the DLM Local Network .................... 2 RJ-45 ports
DLM Local Network characteristics when using LMRC-11x/2xx
room controllers:
Low voltage power provided over Cat 5e cable (LMRJ);
max current 800mA. Supports up to 64 load addresses,
48 communicating devices including up to 4 LMRC-10x
series and/or LMPL-101 controllers.
Free topology up to 1,000’ max.
Environment ................................................. For Indoor Use Only
Operating Temperature .................32° to 131°F (0° to 55°C)
Storage Temperature ...................23° to 176°F (-5° to 80°C)
Relative Humidity .......................5 to 95% (non condensing)