FACTORY SETTINGS
At this point in time, the locking system can be closed and opened with one or more installation cards. To do this, the
lock must be connected to a controller for power supply. The installation card can no longer be used after a master
card has been programmed or after the lock has been programmed in the LEHMANN Management Software LMS.
CARE & MAINTENANCE
U
Do not spill any liquid over or into the individual components of the lock.
U
Only clean the components of the locking system with a clean, soft and slightly damp cloth.
U
Do not use any cleaning agents containing abrasives or solvents, as these may damage the housing.
Glass cleaner, thinner, alcohol, gasoline or liquids containing ammonia are not suitable for cleaning.
U
Improper handling of all electronic and mechanical components that deviate from the description in this user
manual can lead to malfunctions.
U
Check components for damage and replace damaged parts immediately.
FUNCTIONAL DESCRIPTION
With the locking system you can lock and unlock your furniture. RFID technology based on 13.56 MHz is used as the
„key“. There are two operating modes available:
Operating mode
Description
Assigned use
There is a fixed assignment between transponders (user cards) and the lock. Transponders are
programmed or deactivated at the lock by using a master card or the LMS. The lock thus allows
selective access authorizations to be granted so that only authorized users with an authorized
transponder receive access. A transponder can be programmed at several locks in the mode
„assigned use“ at the same time. Up to 250 different transponders can be programmed per lock.
Shared use
A user can use a lock of his choice with a transponder. If a lock is closed with a transponder, the
transponder and lock are linked to one another. The transponder cannot be used on any other lock
in „shared use“ mode and the lock does not accept any further transponders. This coupling is only
deactivated when the user opens the lock again with his transponder. The transponder can now be
used for another lock.
Card type
Description
Installation card
(only for assembly
and testing
purpose)
The installation card can be used especially for assembly and testing purposes in order to perform
basic functions on the lock (opening and closing). This card is for universal use. Prior programming of
a master card is not necessary. After programming the lock with a master card or with the LEHMANN
Management Software LMS, the lock is disabled for the installation card.
Master card
For commissioning, a master card must be programmed. The master card is required for starting and
terminating programming operations. This also includes the programming of user cards in “assigned
use“ mode. The master card also enables the so-called Facility Manager function and the emergency
opening of the lock. One master card can be programmed per lock. You can use one master card for
several locks.
User card
User cards are used to open and close the lock. In “assigned use“ mode, up to 250 user cards can be
programmed on one lock. In “shared use“ mode, one user card can be used temporarily on one lock.
It is possible to program one user card on several locks in “assigned use“ mode, and at the same time
on one lock in “shared use“ mode.
OVERVIEW OF TRANSPONDER CARDS