background image

BD

A M610 L033-A03 2021-08-17 (GB)

12

DELETING INDIVIDUAL TRANSPONDER CARDS 

(only for “Assigned use“ mode)

Insofar as further user cards were programmed on the lock, these can continue to be used on this lock after an 
individual user card has been deleted. For the deleting process, the lock must be open. To do this, first carry out an 
emergency opening with the master card if necessary (see Emergency opening, P. 11).

Should the user card be lost, then please proceed as follows.

Deleting individual user cards

Master

       

Hold the master card  
in front of the reader

    

        

  

    

  

User

Hold the user card to  
be deleted in front of  
the reader.

    

    

            

    

             

            

                

Master

Hold the master card  
in front of the reader.

    

  

    

             

DELETING ALL TRANSPONDER CARDS 

(only for “Assigned use“ mode)

The deleting process can only be carried out when the lock is open. Should there be no authorised user card to hand, 
first perform an emergency opening using the master card.

Deleting all user cards

Master

       

IMPORTANT: Hold the 
master card in front of the 
reader until all the following 
optical and acoustic signals 
have been received.

    

                                  

  

    

                

                                

                                

 

5 seconds

    

    

            

    

             

            

  

Master

IMPORTANT: Hold the 
master card in front of the 
reader until all the following 
optical and acoustic signals 
have been received.

                

    

    

  

      

                   

             

            

                               

 

5 seconds 

              

                               

Summary of Contents for L033-A03

Page 1: ...g the Master Card 9 Programming the User Cards Closing and Opening 10 Unauthorised Transponder Cards Facility Manager Function Emergency Opening 11 Deleting Individual Transponder Cards Deleting all Transponder Cards 12 Changing the Operating Mode Deactivating and Activating Acoustic Signals 13 Resetting to Factory Settings 14 Battery Warning 15 Emergency Power Supply Firmware Update 16 Reordering...

Page 2: ...d with master and programming cards or with the LEHMANN Management Software LMS These operating instructions describe how to use the locking system with master and programming cards The software LMS and the corresponding documents can be found at https lms lehmann locks com TECHNICAL SPECIFICATIONS SAFETY PRECAUTIONS U When replacing the batteries make sure that the polarity and position of the ba...

Page 3: ...a spacer is suitable for use on metallic surfaces Please note that the distance between two or more RFID readers must be at least 5 cm This system is not intended for push to open applications If required this needs to be tested on individual basis Lock operating mode Description Assigned use factory settings There is a fixed assignment between the transponder cards and the locks The user cards ar...

Page 4: ...r card is not necessary After a master card has been programmed for the first time the lock is disabled for the installation card The use of an installation card is optional Master card For complete commissioning a master card must be programmed for both operating modes The master card is required for starting and terminating programming operations This also includes the programming of user cards ...

Page 5: ...rews for mounting the lock and the RFID reader must be adapted Components for M610 1 M610 2 4x screw 4 5x16 for M610 3 2x battery CR123A 4 Cover for M610 5 Striker plate 6 3 x flat headed screw 3 0 x 15 mm for striker plate only included in single set packaging 7 Pin for battery compartment Components for RFID reader L033 A03 8 Cabel 9 RFID reader L033 A03 10 2x thermoplastic screw 3x20 11 Spacer ...

Page 6: ...surface except Omega profiles The locker lock M610 is available in two versions right or left mounting Please ensure the correct installation position of the lock and the RFID reader Tighten the screws hand tight with max 0 7 Nm Please note the different mounting positions and drilling pattern for the RFID readers CAUTION For mounting the RFID reader L033 A03 without spacer please use drill holes ...

Page 7: ...33 A03 RFID reader L033 A03 with spacer 6 8 14 4 4 22 14 6 27 39 1 15 5 4 5 44 10 6 8 14 4 4 22 14 6 27 39 1 15 5 4 5 44 10 Striker plate 105 94 94 105 14 25 27 5 5 4 9 4 5 25 64 14 29 5 76 14 5 2 Ø 5 2 Ø 64 28 5 75 14 8 5 5 4 64 28 5 5 2 75 14 64 5 2 29 5 76 14 64 ...

Page 8: ...d the sockets are properly aligned CAUTION Use only CR123A primary batteries Open the battery compartment cover by inserting the pin into the small holes and releasing the cover Lift the cover off at the same time Insert the batteries CR123A in the battery compartment Use only CR123A primary batteries Make sure that the batteries are correctly inserted in the battery compartment and wait until a l...

Page 9: ...MASTER CARD Irrespective of the desired operating mode a master card must always be programmed before further programming and operation Only one master card can be programmed per lock The programming of the master card can be carried out when the lock is closed as well as when it is open If the lock is closed after the master card has been programmed the next step must be an emergency opening see ...

Page 10: ...user cards see Closing and Opening P 10 After programming the user cards can open and close the lock Programming user cards Master Hold the master card in front of the reader User Hold the user card in front of the reader The card is accepted and programmed This process can be repeated to program multiple user cards Card is not accepted Master Hold the master card in front of the reader CLOSING AN...

Page 11: ...k opens for 30 seconds and then closes automatically After this automatic closure authorised user cards can continue to be used in Shared use mode as well as in Assigned use mode EMERGENCY OPENING In the event that one or all authorised user cards are currently not available an emergency opening can be effected with the master card Please note that the lock remains open after emergency opening In ...

Page 12: ...ter Hold the master card in front of the reader User Hold the user card to be deleted in front of the reader Master Hold the master card in front of the reader DELETING ALL TRANSPONDER CARDS only for Assigned use mode The deleting process can only be carried out when the lock is open Should there be no authorised user card to hand first perform an emergency opening using the master card Deleting a...

Page 13: ... Mode in front of the reader Shared use mode is selected Shared use P1 Mode Hold the programming card No 1 P1 Mode in front of the reader again Assigned use mode is selected Assigned use Master Hold the master card in front of the reader DEACTIVATING AND ACTIVATING ACOUSTIC SIGNALS Acoustic signalling is activated when the system is delivered You have the option of deactivating the acoustic signal...

Page 14: ... Sound in front of the reader again Acoustic signals are activated again Acoustic signals are activated Master Hold the master card in front of the reader RESETTING TO FACTORY SETTINGS RESET If a reset to factory settings is required all master and user cards are deleted With an installation card the basic functions close and open can be carried out The bolt is retracted and the lock must be repro...

Page 15: ... warning takes place in two phases The settings are saved even without a power supply e g in case of battery replacement or in case the batteries should be completely empty Battery replacement should be carried out within 5 minutes Battery warning Phase 1 Before an action can be carried out closing opening programming a battery warning is given The batteries should be replaced The battery warning ...

Page 16: ...operating instructions of the power bank e g for starting and ending the charging process U Please do not perform any further actions until the RFID reader gives an acoustic and a visual signal see Acoustic and visual signals when inserting the batteries U Then open the lock with an authorised transponder card Here you can use either a programmed user card or the master card for emergency opening ...

Page 17: ...ransponder card cannot be programmed Possible reasons Storage space is used up Card is not compatible Master card has not yet been programmed Available storage space in the lock is used up Possible reasons 50 user cards have already been programmed in the lock Bolt warning the bolt does not move to the end position Possible reasons Striker plate or lock not correctly installed Furniture door is no...

Page 18: ... the functions open close with an authorised user card again when the furniture is open If the lock should work properly please check to see if the bolt can extend correctly when the furniture is closed see installation recommendation If you are using an existing user card not from the Lehmann company check to see whether the appropriate write permission has been given for the transponder card Loc...

Page 19: ...BDA M610 L033 A03 2021 08 17 GB 19 NOTES ...

Page 20: ...3 A03 2021 08 17 GB 20 LEHMANN Vertriebsgesellschaft mbH Co KG Postfach 26 20 D 32383 Minden Fon 49 571 50 599 0 Fax 49 571 50 599 822 info lehmann locks com www lehmann locks com DIN EN ISO 9001 2008 zertifiziert ...