BD
A M410 T
A03 / 2019-09 (GB)
11
FACTORY SETTINGS
The following settings apply for the locking system as delivered from the factory:
U
Free Code mode
U
The lock is in open position
U
Master code: 9-0-8-0-7-0-5-5-5-5
U
Emergency opening code: 1-0-1-0-5
U
Automatic locking is deactivated
U
Automatic opening is deactivated
ATTENTION:
It is highly recommended to change the factory set master code and factory set emergency
opening code!
OPENING & CLOSING IN FREE CODE MODE
The lock must be in open position.
To close, you can enter any 3 to 10 digit code. When entering, make sure that each key input is acknowledged by a
light signal at the LED display.
After opening by entering the correct code, the previous code will be deleted. The lock can now be closed again with
any 3 to 10 digit code.
If an invalid code is entered, the LED display flashes red three times.
Close (example: 1-4-5-6)
Keys
1
4
5
6
Display
Lock closes.
Open (example: 1-4-5-6)
Keys
1
4
5
6
Display
Lock opens.