BD
A M610 LE
GIC L043-A03 2022-07-12 (GB)
15
P3: Reset
Hold the programming card
No. 3 (P3: Reset) in front
of the reader.
P3: Reset
Hold the programming card
No. 3 (P3: Reset) in front
of the reader again.
Master
Hold the master card
in front of the reader.
During initialisation, no
transponders should be
placed within the read
range of the RFID reader.
to about
10 seconds
about 3 seconds
CONFIGURE RFID SYSTEM WITH LEGIC SYSTEM AUTHORIZATION MEDIA (SAM)
Special permissions and configurations are transferred to the RFID reader by using the SAM 63 card that is part of the
LEGIC Master-Token System-Control (MTSC). Following this, only LEGIC advant transponders or user cards with the
associated digital stamp can be used on the RFID readers. Master and programming cards are still usable.
The lock must be open in order to program the SAM 63 card. Detailed information about the LEGIC MTSC is available
at
www.legic.com
.
Configuration with LEGIC SAM 63 card
Master
Hold the master card
in front of the reader.
SAM 63
Hold the LEGIC SAM 63
card in front of the reader.
Master
Hold the master card
in front of the reader.
If the lock is in delivery state (no master card programmed), you can hold the card LEGIC SAM 63 directly in front of
the RFID reader for configuration without a master card.