Press the button.
The quantity adaptation is displayed in %.
AUTO
Press the button.
The spreading material, the working width and
the output kg/ha are displayed.
The speed impulses per metre are set.
The control is ready to start.
In GPS mode, no impulse setting is required.
The spreading value stored in the spreading table can be changed temporarily.
AUTO
AUTO
Set the quantity adaptation.
Press the button for around
five seconds.
Press the + button to increase
the spreading value up to 50%.
Press the - button to decrease
the spreading value up to 50%.
Press the button to return to operating
mode.
Qty. adaptation
0%
AUTO
Press the button.
The quantity adaptation has been stored. The quantity adap-
tation remains stored until the spreading material is switched
or changed in the display.
4.14 Operating SuperVario
®
X in automatic mode
Connect the speed signal (GPS receiver or 7-pin signal socket).