Operation
16 / 52
1.0
Vento
®
1. Mount the sensor in the joint section of the lower link.
2. Mount the magnetic encoder to the lower link.
3. Set the position of the sensor and the magnetic encoder. Maximum distance 8 mm.
Hydraulics lowered:
Sensor is not allowed to be in field of magnetic encoder. Dosing stops (see EHR setting: high active or low active).
Hydraulics lifted:
Sensor must still be in field of magnetic encoder. When the hydraulics are lifted, the sensor must not leave the field
of the magnetic encoder, as otherwise the dosing will start again.
3.4.6 Setting setting signal for electronic lifting gear control (EHR)
The spreader is equipped ex-works with EHR signal communication (socket). The hydraulic signal is taken from the
7-pin EHR socket of the carrier vehicle or from the sensors attached to the lower link (install magnet with sensor on
lower link - option).
Depending on the carrier vehicle, the signal is output on lifting or on lowering. Check the EHR signal is set correctly
and correct it if necessary.
Press the Automatic dosing key for approx. 6 seconds.
Qty. d t tio
Press the toggle switch twice.
C l. w
l
.
Y S
Press the key to set the EHR signal.
EHR signal for lifting:
High active is displayed
EHR signal for lowering:
Low active is displayed
s
c e
Press the Automatic dosing key to return to the operating
mode.
Press the Automatic dosing key for approx. 6 seconds.
Press the toggle switch three times.
Press the toggle switch to display the setting for the speed sen-
sor of the EHR signal. Adapt the speed signal with the
+/-
keys.
Factory setting: 130 /m