Operation
Vento
®
1.0
23 / 52
Error
Possible cause
Action to take
Drive belt wear
Check drive belt and renew if neces-
Excessive differences in hose
length means the air flow in the
blocked hose is too low
Install the hose at the far left.
Discuss the problem with the prod-
uct specialist, possibly install cus-
tomer-specific throttle orifices to
control the air flows.
Blockage of particular hoses
Hose routed with excessively tight
bending radius
Route the hose with the largest pos-
sible bending radius and as few
curves as possible.
Blower does not function
Heavy contamination leads to
blockage
Clean the blower when dry, see
.
Hose grommet does not stay in
place or fails to engage
Pressure element in the holder
contaminated
Renew the pressure element if nec-
essary.
Distance between the sensor and
wheel nuts too large
Check the distance and set if neces-
sary. Distance should be less than
or equal to 4 mm.
Contact problems
Check the wheel sensor/control pan-
el plug connection.
Check the cables.
No signal from the wheel sensor
Check the counting points.
Distance between the sensor and
magnet too large
Check the distance and set if neces-
sary. Distance should be less than
or equal to 8 mm.
Sensor installed in wrong direction
Note the installation direction of the
sensor.
No signal from the lifting gear mag-
netic sensor
Check the cables.
Summary of Contents for Vento