2020-02
CANVASA II + II can filling machine operating manual
25
Attention! Machine damage due to impure compressed air
The machine requires properly conditioned compressed air for operation. All pneumatic
equipment is operated with oil-free compressed air unless otherwise indicated.
Important information!
The following quality classes as per ISO 8573-1 must be adhered to:
Solids: Class 5, max. particle size 40 µm
Water content: Class 5, max. pressure dew point +7 °C
Oil content: Class 4, max. oil concentration 5 mg/m3.
Compressed air that is contaminated by particles, oil, water or other media can cause seri-
ous damage to the machine.
Damage caused by contaminated compressed air shall not be covered by the warranty!
Important information!
The mains pressure of the compressed air/CO2 supply must not exceed 6 bar. An operating
pressure of 5 bar must be ensured in each case.
Water
Important information!
Drinking water quality is necessary
for can spraying and high pressure spraying.
The drinking water supply network must be connected in accordance with the applicable local
legislation and must only be carried out by a licensed fitter.
Waste water
The waste water produced as a whole does not contain any special substances and can be dis-
posed of in the local sewage system.
Electrical connection
Risk of death from electric shock!
All installation work must be carried out with the power switched off!
Important information!
The following points must be followed without fail!