2020-02
CANVASA II + II can filling machine operating manual
62
Fault
Possible cause
Remedy
Motor overloaded
Motor defective
Ventilation openings contaminated
Clean openings
Faults occur when the
lid is fed in
Bottom lid gassing displaced
Realignment via adjusting
ring
Unusually strong vi-
brations occur during
sealing
Incorrect rotary star wheel position. Manually bring the rotary star
wheel into the ideal position
and reset the zero point.
The cans are not
properly sealed
The strokes of the sealer are set
incorrectly.
Readjustment of the stops
High-pressure injec-
tion heating (optional)
is not heating
Temperature limiter in the heater
has tripped
Reset the limiter
Starting machine after emergency stop
Proceed as follows after the emergency stop has been triggered:
Identify the trigger for the fault
Rectify the fault
Unlock emergency stop switch
Acknowledge fault with the "Reset" button