Group 12
Appendix - Connection Examples for the Interfaces
Page 379
JET3 Series
Release 2.02
12.2 Connection examples for the interfaces
The wiring examples which are described in the following are only for support. Other
combinations, actuators, sensors and switching elements are of course possible and cannot
be described completely here.
For the connection please pay attention to the specifications which are described for the plug
assignment!
12.2.1 Interface X 3 - Outputs
The described examples are possible at all 8 outputs.
Inputs:
Is used when a printer-output is connected to an input of a external logic (e.g. PLC).
Due to the high resistance of the low level signal of the output driver, a 20kOhm Pull-
down resistor is recommended.
The resistor can be dropped if the following input wiring has already an accordant low
input resistance.
LED's:
LED can be connected by a series resistance. (as in the example for a LED with U
F
= 2V
and I
nominal
= 20mA)
Inductive Loads:
For the usage of inductive loads (relay, motors etc.) a parallel-diode is provided to avoid
a turning-off peak.
Lamps or Resistors:
Lamps or other resistor loads can be directly connected to the output, but the sum of the
output loads should not be higher than 700 mA (in sum of all outputs together).