Page 58
Transport/Start up
Group 5
Release 2.02
JET3 Series
Basic data /Recommended working conditions:
Signal
Parameter
Value
All signals
Input level High
15 up to 30V
Input level Low
-3,5V up to 3,5V
(or high resistance)
Input resistance
6,8kOhm
Increment Counter/
Reset Counter
Minimum pulse width
2 ms
Power ON
Minium pulse width
2,5 s
Jobselect 0-9
Maximum duration
of bounce
10 ms
(2)
Input 0-5
Minimum pulse widths
Depending on assigned function
(see following table)
In the following table you will find the minimum pulse widths which are required to release
the assigned function at the X4 plug.
Function
Minium pulse width
Open nozzle
300ms
Close nozzle
300ms
Print start
500ms
Print stop
500ms
Turn off printer
750ms
Mirrored horizontally
200ms
Gauger synchronization signal
200ms
INFORMATION
The function allocations of the inputs 0 up to 5 happens by the software of
the the printer in the menu
Settings
I/O-Settings
Inputs
.
You will find a circuit diagram of the interface in the manual appendix!
(1)
all 24V power supply outputs on X1, X3, X4 and X5 are distributed over a common resettable fuse
with 700mA max. current.
Please ensure that the sum of current are not exceed 700 mA.
(2)
If one or more of the jobselect inputs were changed the changes must be completed
( = all signals are stable) within this time.