Page 280
Job Editor
Group 8
Release 2.02
JET3 Series
8.5.3.3 Encoder resolution
The parameter
<Resolution>
is calculated from the impulses per rotation generated by
the encoder used and the length of one rotation. The dimension is
pulses/mm
.
Example:
An encoder which generates 10.000 impulses/rotation with a friction wheel
and which has a circumference of 200 mm is used.
Calculation: Resolution
= Impulses/Rotation : Circumference
= 10.000: 200 = 50 (Pulses/mm)
Important
A wrong setting of the parameter
<Resolution>
may cause improper print outs.
8.5.3.4 Internal speed
With the
<Internal encoder source>
selected (please see chapter
for details) the production speed respective the printing speed
has to be set as a parameter. This value is entered directly in the input field / display field
<Internal speed >
. The dimsion is
m/min
.
ATTENTION
A varying production speed cannot be detected with the encoder source
<
Internal>.
Only the
<Internal speed>
set will be used to calculate the
<StrokeGo>
signals. Therefor a varying production speed may cause
improper print outs:
If the production speed is higher as the value set, the printout will be
stretched.
If the production speed is lower as the value set, the printout will be
compressed.