Scan Rate per Channel
– for 512 Samples per
Scan
381 scans per second
Scan Interval
42 scans per metre
Positioning
•
Two integrated encoders on the rear wheels
•
GNSS antenna or Total Positioning System
(TPS – surveyor kit only)
Temperature
Operating temperature [°C]
Storage temperature [°C]
−10 to +40
−40 to +70
GEB242:
−10 to +55
−40 to +70
Protection against water, dust and sand
Protection
IP65 (IEC 60529)
Humidity
Protection
Max 95% non-condensing
The effects of condensation are to be effectively counteracted by periodi-
cally drying out the instrument.
8.2
Conformity to European Regulations
The equipment conforms to the following requirements set by EC regula-
tions, including subsequent modifications, and to the legislation set by the
member states that implement these regulations:
2014/53/EU Radio Directive
Warning: this equipment is destined for use in industrial environments (Class
A apparatus). In residential, commercial and light industry environments, this
apparatus may generate radio interference: in this case, the user may be
required to operate while taking appropriate countermeasures.
The apparatus is sensitive to the presence of external electromagnetic fields,
which may reduce its performance.
Receiver test according to EN 302 066 v. 2.1.0
The unit has been tested according to the provision of the EN 302 066 v.
2.1.0. Specifically, for the receiver test (that tests the influence of an inter-
ferer signal to the device), the following performance criterion has been
used (see ETSI TS 103 361 v.1.1.1) .
Performance criterion: The difference D between the R
x
signal noise
(increased by an interferer) and the maximum input signal for the R
x
in the
linear region of operation.
Level of performance: D
min
> 30 dB
Environmental
specifications
Conformity to Euro-
pean regulations
Technical Data
55