14
ScanStation P16, Setting Up the Instrument
Setup with Laser
Plummet step-by-
step
1. Extend the tripod legs to allow for a comfortable working posture (
a
). Position
the tripod approximately over the marked ground point, centring it as well as
possible (
b
).
2. Place the tribrach on the tripod (
c
) and secure it with the central fixing screw (
d
).
Shield the instrument from direct sunlight and avoid uneven temperatures
around the instrument.
004313_001
a
a
a
b
c
d
j
j
j
e
i
h
k
f
g