50
Scan duration:
Available commands:
Field
Description
Resolution
Selection of fixed resolution settings.
Est Time
Estimated time for a scan using the current settings.
Resolution
[mm@10 m]
Estimated scan duration [HH:MM:SS] for a full dome scan
50
00:20
25
00:33
12.5
00:58
6.3
01:49
3.1
03:30
1.6
13:33
Command
Function
Store
Store current scan parameters and return to