User Interface
SPRINTER 100/100M/200/200M
21
9.
AutoOFF
ON 15 min /
OFF
Power saving function. If set to ON 15 min, the
instrument will switch off about 15 minutes after
the last key press.
In the case of OFF, the instrument will be
permanently switched on
10.
Rounding
Precise/
Standard
Setting of minimum display reading:
In metric: Standard = 0.001m for height and
0.01m for distance.
Precise = 0.0001 m for height and 0.001m for
distance
In Ft: Standard (Int. and US ft) = 0.01 ft and
distance = 0.1 ft
Precise = 0.001 ft for height and 0.01 ft for
distance.
In Ft in 1/8 inch: Precise & Standard =
ft-inch-1/8 inch for height and distance
11.
Beep
ON/OFF
Acoustic signal trigger key ON or OFF
12.
RS232 (appli-
cable to
SPRINTER
100M/200M)
Baudrate
Parity
Stop Bit
Data Bit
1200, 2400, 4800, 9600, 19200, 38400
None, Odd, Even
1, 2
7, 8
No.
Sub Menus
Selections Descriptions