SPRINTER 100/100M/200/200M
User Interface
Clearing all the
existing entry field
Highlighting the first entry field with "SPACE" and press ENTER key to clear the
entire last reduced level input value.
Default Reference
Reduced Level
•
If no Reference reduced level is input; the default value equals to zero, i.e. 0.000.
•
The display value is to 4 and 3 decimals in meter and feet (Int and US ft) respectively
for Precise setting; 3 and 2 decimals in meter and feet (Int and US ft) respectively for
Standard setting. For ft in 1/8 inch, the display value will be shown in Precise setting.
Change reduced
level value
•
Once Reference staff measurement is measured as in section "5.3.2 Height Differ-
ence, Reduced Level, Height and Distance Measurement (internal Memory not
active)", then the last input REFERENCE reduced level cannot be changed. At this
stage, if any attempt to change the last input REFERENCE reduced level in menu
INPUT RL, a "RL Change Not Allowed!" message will be prompted.
•
To change the input REFERENCE reduced level, follow these steps:
• Discontinue the present reduced level measurement by pressing
HEIGHT/DISTANCE key to exit to default measurement.
• Go to menu select INPUT RL and carry on with the steps in section 4.7.1 to edit a
new REFERENCE reduced level value.
• Start reduced level measurement with NEW REFERENCE reduced level as in