background image

19

Working with BLUETOOTH®

Leica DISTO™ D3a BT 776750 gb

D

GB

F

I

E

P

NL

DK

S

N

FIN

J

CN

ROK

PL

H

RUS

CZ

constant to the required value using the 

 or 

 

button. Press the 

 button to save the constant.

Historical storage

 Press this button 

twice

 and the previous 20 

results (measurements or calculated results) are 
shown in reverse order. 

The 

 and 

 buttons can be used for navigation. 

 Press this button to use a result from the 

summary line for further calculations. 

Pressing the 

 and 

 buttons at the same 

time erases all the values in historical storage.

Timer (self-triggering) 

 Press this button to set a 5-second time delay. 

or 

 Press and hold down this button until the 

desired time delay is reached (max. 60 seconds).

Once the key is released the remaining seconds until 
measurement (e.g. 59, 58, 57...) are displayed in a 
countdown. The last 5 seconds are counted down 
with a beep. After the last beep the measurement is 
taken and the value is displayed.

)

The timer can be used for all measurements.

Working with BLUETOOTH®

Switching on BLUETOOTH® / 
sending measurements

A quick press on the 

 - key starts DISTO™ BLUE-

TOOTH®. The data connection must then be estab-
lished out from a Pocket PC / PC by the application 
software. A BLUETOOTH® - icon will appear in the 
display until this has been successfully completed. 
BLUETOOTH® automatically switches off if the 
connection to the Pocket PC / PC is not established 
within 240 sec from when the BLUETOOTH® was 
switched on. 

)

Whilst the first connection between the 

Pocket PC/PC and the DISTO™ is being established, a 
prompt for the Pin-code of the DISTO™ may be 
displayed. In this case, enter the code 0000 into your 
Pocket PC/PC.

Switching off BLUETOOTH®

BLUETOOTH® switches off as soon as the DISTO™ is 
switched off. 

Summary of Contents for DISTO D3a BT

Page 1: ...Safety Instructions Symbols used The symbols used in the Safety Instructions have the following meanings WARNING Indicates a potentially hazardous situation or an unintended use which if not avoided...

Page 2: ...perma nently habitable by humans do not use the product in explosion hazardous areas or in aggressive envi ronments Areas of responsibility Responsibilities of the manufacturer of the orig inal equip...

Page 3: ...asuring sensor not as a control device Your system must be configured and operated in such a way that in case of an erroneous measurement malfunction of the device or power failure due to installed sa...

Page 4: ...vision reception which can be deter mined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate th...

Page 5: ...rdance with IEC60825 1 2007 Radiation safety of laser products Laser Class 2 products Do not stare into the laser beam or direct it towards other people unnecessarily Eye protection is normally afford...

Page 6: ...orrect polarity 3 Close the battery compartment again Replace the batteries when the symbol flashes perma nently in the display Only use alkaline or rechargeable batteries Remove the batteries before...

Page 7: ...ng bracket until it locks in place then push the positioning bracket lightly to the right to fold it out fully A built in sensor automatically detects the orienta tion of the positioning bracket and a...

Page 8: ...ll up constant value 11 Historical memory call up values 12 Spirit level numeric 13 Battery status 14 Area volume 15 Tilt 16 Horizontal distance measurement using tilt 17 Triangle area 18 Timer 19 Men...

Page 9: ...The instrument can be specifically configured to your personal requirements General description button pressed long You are in the the units set and the first menu item Unit are displayed button press...

Page 10: ...rements with a tripod To do this select ON in this menu item You can switch the reference on the tripod on or off The setting can be seen on the display Beep You can switch the beep on or off Level in...

Page 11: ...hows the battery symbol until the next button is pressed Pressing this button for longer switches the instrument off The instrument switches off automatically after six minutes of inactivity CLEAR but...

Page 12: ...nd up to max a transverse tilt of 10 Press the button for longer to display additional information on the measurement for example the tilt angle the distance measured and the indi rect height Press bu...

Page 13: ...evice switches off automatically after 15 minutes Functions Addition subtraction Distance measuring The next measurement is added to the previous one The next measurement is subtracted from the previo...

Page 14: ...ent e g width Press this button to take the third length measure ment e g height The volume then appears in the summary line Press the button for longer to display additional room information such as...

Page 15: ...first two measurements and the perimeter of the triangle Stake out function Two different distances a and b can be entered into the instrument and can then be used to mark off defined measured length...

Page 16: ...er a or b As soon as the stake out point is reached the beep changes The function can be stopped at any time by pressing the button Indirect measurement The instrument can calculate distances using Py...

Page 17: ...possible Press and hold down this button to trigger continuous measurement sweep the laser back and forth and up and down over the ideal target point Press to stop continuous measurement 2 The result...

Page 18: ...s 2 Triggers the measurement After the second measurement the value is adopted The display flashes 3 Press and hold down this button to trigger continuous measurement Sweep the laser up and down over...

Page 19: ...asurement e g 59 58 57 are displayed in a countdown The last 5 seconds are counted down with a beep After the last beep the measurement is taken and the value is displayed The timer can be used for al...

Page 20: ...g successfully received by the Pocket PC PC then no new measure ment can be processed The Info code 240 appears in the display if no data transmission has taken place after 2 seconds Press the key and...

Page 21: ...e Remedy Error Hardware error Switch on off the device several times If the symbol still appears then your instrument is defective Please call your dealer for assistance Cause Remedy Distance measurem...

Page 22: ...ss liquids e g water or dust free glass Styrofoam or similar semi permeable surfaces Aiming at high gloss surfaces may deflect the laser beam and lead to measurement errors Against non reflective and...

Page 23: ...ope or camera Warranty The Leica DISTO D3a BT comes with a three year warranty from Leica Geosystems AG More detailed information can be found at www disto com All illustrations descriptions and techn...

Page 24: ...24 Appendix Leica DISTO D3a BT 776750 gb D GB F I E P NL DK S N FIN J CN ROK PL H RUS CZ...

Page 25: ...Quality Systems ISO standard 9001 and Environmental Management Systems ISO standard 14001 Total Quality Management Our commitment to total customer satisfaction Ask your local Leica Geosystems agent f...

Reviews: