background image

Options and Configuration 
 
The following keys and key combinations can be used to change various options when 
pressed for 2 seconds. 
 
MEM: 

change distance unit 

REF: 

switch to permanent front reference 

CLR: 

power off 

MEM and SMART: 

angle unit: degrees/grad 

MEM and FUNC: 

silent mode on/off 

MEM and MINUS: 

backsight mode on/off 

REF and MINUS: 

beep on/off 

REF and PLUS: 

display illumination on/off 

REF and FUNC: 

back reference: case/endpiece 

CLR and SMART: 

calibration mode on/off 

CLR and MEM: 

clear unsent memory 

CLR and FUNC: 

Bluetooth on/off 

CLR and MINUS: 

locked power off 

SMART and MINUS: 

triple shot check on/off 

 
The distance and angle units are used for the numbers in the display only; they have no 
influence on the stored and transmitted values. 
 
 
Backsight Mode 
 
If the backsight mode is turned on, the measurements are reported as if they were measured in 
the opposite direction. The sign of the inclination is reversed and 180° is added to the 
azimuth. On the display a down arrow is shown near the Laser symbol when the option is 
turned on and whenever a backsight measured memory value is shown. 
 
 
Triple Shot Check 
 
If the triple shot check option is turned on, the device checks for three nearly identical 
measurements in a row. If a triple is detected the device beeps twice and shows an ‘identical’ 
sign ( 

 ) to the right of the measured values. Three shots are considered nearly identical if the 

pairwise comparison results in a distance difference < 5cm and a directional difference < 3% 
(1.7°). PocketTopo uses the same measure to distinguish survey shots from splay shots. A 
small triangle (   ) is shown a in the lower left corner of the display if the check is switched 
on. 
 
 
Factory Reset 
 
Press CLR, FUNC, and MEM for 5 seconds to reset the device to the original state. 
The memory is erased completely, the user options are set to default values, and the 
calibration coefficients are reset to a neutral calibration. To preserve the calibration, read the 
calibration coefficients from the device, reset the device, and write the coefficients back to the 
device. 

Summary of Contents for DistoX2

Page 1: ...milarly to the original X310 The display shows the Azimuth in the first the inclination in the second and the distance in the bottom line It stores up to 1000 measurements to be inspected later or transferred over the Bluetooth connection Main Functions DIST power on start Laser measure distance CLR cancel current operation switch Laser off REF change distance reference TIMER start timer automatic...

Page 2: ... 180 is added to the azimuth On the display a down arrow is shown near the Laser symbol when the option is turned on and whenever a backsight measured memory value is shown Triple Shot Check If the triple shot check option is turned on the device checks for three nearly identical measurements in a row If a triple is detected the device beeps twice and shows an identical sign to the right of the me...

Page 3: ...luetooth is switched on the device is discoverable and connectable at any time It appears as DistoX nnnn where nnnn is the serial number of the device It provides a serial connection SPP named serial The device needs no pairing key If the connecting device request one it is 0000 four zeroes To read the results from the device a special program is needed PocketTopo This runs either on a PC or on a ...

Page 4: ...creen to the next Use the SMART key to return to the previous screen Screen 1 Battery Shows the actual battery voltage and the battery chemistry used for the battery level indicator LI for LiPo or AL for Alkaline Press the FUNC and SMART keys for 5 seconds to change the battery chemistry Be sure to use the correct setting LI default for a built in rechargeable battery or AL for AAA primary cells S...

Page 5: ...ark the rear exit point of the Laser beam picture Place this point as near as possible to the survey point Switching the display illumination off completely saves a lot of power For best performance the device should be calibrated in regular intervals Error Codes If an error occurs during a measurement the text Info appears on the screen together with one of the following error codes 252 Temperatu...

Page 6: ...proper calibration Features Selectable Units m ft inch grad Memory capacity 1000 measurements Laser Type 635nm 1mW class II Mechanical Size 55 x 31 x 122mm Weight 150g Protection IP65 Electrical Battery voltage 1 5 5 5V LiPo charger input 4 5 6V Power consumption Bat 4V Bat 3V original X310 Bat 3V Idle incl Bluetooth 4mA 5mA 36mA Illumination on 9mA 11mA 43mA Laser on 88mA 110mA 120mA ...

Reviews: