Silent Mode 
 
In Silent mode the device does not transfer measured data even if a PDA is connected. The 
data is still saved to memory but immediately marked as sent. The display shows three dashes 
(---) in the top right corner when in Silent Mode. Press MEM and FUNC for 2 seconds to 
switch silent mode on and off. 
Pressing CLR and MEM for 2 seconds marks all measured data as sent without entering 
Silent mode. 
 
 
Charging the Battery 
 
To charge the battery, a 5V source must be connected to the charging connector in the battery 
compartment. Any phone charger with a micro USB connector will do the job. 
 
The battery indicator in the display shows the actual battery level. It flashes when a charger is 
connected and stops flashing when the battery is fully charged. 
 
 
Device Information 
 
The FUNC key can be used to show a sequence of information screens. FUNC key in idle 
mode shows the first screen. FUNC again navigates from one screen to the next. Use the 
SMART key to return to the previous screen. 
 
Screen 1: Battery 
Shows the actual battery voltage and the battery chemistry used for the battery level indicator: 
“LI” for LiPo or “AL” for Alkaline. 
Press the FUNC and SMART keys for 5 seconds to change the battery chemistry. Be sure to 
use the correct setting: 
LI (default) for a built in rechargeable battery or AL for AAA primary cells. 
 
Screen 2: Versions 
Shows the hardware and firmware version numbers and the serial number of the device. 
 
Screen 3: Display Illumination 
Shows the display illumination level (1 - 10). 
To change the level first press the PLUS and MINUS keys for 2 seconds to allow editing. 
Then press the PLUS or MINUS key to change the value. 
To switch the illumination off completely, use REF + PLUS option mentioned above. 
 
Screen 4: Endpiece Offset 
Shows the actual endpiece offset in mm (-128 - 127). 
To change the level first press the PLUS and MINUS keys for 2 seconds to allow editing. 
Then press the PLUS or MINUS key to change the value. 
Changing the offset is useful for self-made endpieces or other cases where a non-standard 
reference is used. 
 
 
 

Summary of Contents for DistoX2

Page 1: ...milarly to the original X310 The display shows the Azimuth in the first the inclination in the second and the distance in the bottom line It stores up to 1000 measurements to be inspected later or transferred over the Bluetooth connection Main Functions DIST power on start Laser measure distance CLR cancel current operation switch Laser off REF change distance reference TIMER start timer automatic...

Page 2: ... 180 is added to the azimuth On the display a down arrow is shown near the Laser symbol when the option is turned on and whenever a backsight measured memory value is shown Triple Shot Check If the triple shot check option is turned on the device checks for three nearly identical measurements in a row If a triple is detected the device beeps twice and shows an identical sign to the right of the me...

Page 3: ...luetooth is switched on the device is discoverable and connectable at any time It appears as DistoX nnnn where nnnn is the serial number of the device It provides a serial connection SPP named serial The device needs no pairing key If the connecting device request one it is 0000 four zeroes To read the results from the device a special program is needed PocketTopo This runs either on a PC or on a ...

Page 4: ...creen to the next Use the SMART key to return to the previous screen Screen 1 Battery Shows the actual battery voltage and the battery chemistry used for the battery level indicator LI for LiPo or AL for Alkaline Press the FUNC and SMART keys for 5 seconds to change the battery chemistry Be sure to use the correct setting LI default for a built in rechargeable battery or AL for AAA primary cells S...

Page 5: ...ark the rear exit point of the Laser beam picture Place this point as near as possible to the survey point Switching the display illumination off completely saves a lot of power For best performance the device should be calibrated in regular intervals Error Codes If an error occurs during a measurement the text Info appears on the screen together with one of the following error codes 252 Temperatu...

Page 6: ...proper calibration Features Selectable Units m ft inch grad Memory capacity 1000 measurements Laser Type 635nm 1mW class II Mechanical Size 55 x 31 x 122mm Weight 150g Protection IP65 Electrical Battery voltage 1 5 5 5V LiPo charger input 4 5 6V Power consumption Bat 4V Bat 3V original X310 Bat 3V Idle incl Bluetooth 4mA 5mA 36mA Illumination on 9mA 11mA 43mA Laser on 88mA 110mA 120mA ...