128
Technical Data
Modeled surface
precision
Target acquisition
accuracy
2 mm standard deviation
(algorithmic fit to planar HDS grey & white target)
Dual-axis sensor
•
Selectable on/off
•
Resolution 3.6", dynamic range ± 2.0°
Data integrity
monitoring
•
Self-check at startup
•
optional checks using
Cyclone-SCAN
Reflectivity
Accuracy at 25 m
Accuracy at 50 m
18% (dark grey)
δ
3 mm
δ
7 mm
90% (white)
δ
2 mm
δ
4 mm