iCON robot 60/iCON builder 60, Technical Data
52
8
Technical Data
8.1
Angle Measurement
Accuracy
Characteristics
Absolute, continuous, diametric.
8.2
Distance Measurement with Reflectors
Range
Atmospheric condi-
tions
Measurements can be made to reflector tapes over the entire range without external
ancillary optics.
Type
Available
angular accu-
racies
Standard deviation
Hz, V, ISO 17123-3
Display resolution
["]
[mgon]
["]
[°]
[mgon]
iCON
robot 60
1
0.3
0.1
0.0001
0.1
2
0.6
1
0.0001
0.1
5
1.5
1
0.0001
0.1
iCON
builder 60
2
0.6
1
0.0001
0.1
5
1.5
1
0.0001
0.1
9
2.8
1
0.0001
0.1
Reflector
Range A
Range B
Range C
[m]
[ft]
[m]
[ft]
[m]
[ft]
Flat prism (Reflective tape),
CPR105
150
490
170
560
170
560
Flat prism (Cat-eye), CPR105
250
820
250
820
250
820
Builder prism, true-zero
offset, CPR111
450
1500
800
2600
1000
3500
Standard prism (GPR1)
1800
6000
3000
10000
3500
12000
Three standard prisms (GPR1) 2300
7500
4500
14700
5400
17700
360° prism (GRZ4, GRZ122)
800
2600
1500
5000
2000
7000
360° Mini prism (GRZ101)
450
1500
800
2600
1000
3300
Mini prism (GMP101)
800
2600
1200
4000
2000
7000
Reflector tape (GZM31)
60 mm x 60 mm
150
500
250
800
250
800
Machine Automation power
prism (MPR122)
For Machine Control
purposes only!
800
2600
1500
5000
2000
7000
Shortest measuring distance: 1.5 m
Range A:
Strong haze, visibility 5 km; or strong sunlight, severe heat shimmer
Range B:
Light haze, visibility about 20 km; or moderate sunlight, slight heat
shimmer
Range C:
Overcast, no haze, visibility about 40 km; no heat shimmer