Troubleshooting
System starts
Tracking, but no
deviations are
displayed on
screen and dash-
board blinks
•
System has detected a problem
and stops for safety
•
Wrong prism targeted or wrong
moving prism as-signed to
robot
•
Wrong reference line of Job
activated in Design dialog
•
Machine is outside the limits of
the project
•
Check dashboard message
•
Target correct prism and reas-
sign prism to robot (B#, only
with two prism solution)
•
Perform a Tiepoint check to
verify robot orientation (if
necessary new Resection)
•
Check loaded Job and assigned
reference line
•
Drive the machine within the
design extents manually
Dashboard blinks
red continuously
•
Tolerances exceeded
•
Press appropriate dashboard
button and check error message
Machine stops, all
deviations are
shown as “-” or
error
•
Wrong Job or reference line is
loaded in the Job dialog
•
Machine is out of project
•
Check in the Job dialog to see
which design is selected
•
Check that the selected Refer-
ence Line is correct
•
Check Offsets
System is tracking
OK but machine
does not move
•
Stop Rule is active and machine
is outside of the defined toler-
ance range
•
In Pro Deactivate Stop rule and
drive machine to design position
•
As a short-term measure, devia-
tion can be reduced with the
offset and the machine driven to
the design position
•
Care must be taken to re set
stop rules
Problem
Possible cause(s)
Suggested remedies
Summary of Contents for MCR-900
Page 1: ...Leica PaveSmart 3D User Manual Version 5 0 English ...
Page 11: ...How to use this Manual PaveSmart 3D UM 11 ...
Page 21: ...Getting Started PaveSmart 3D UM 21 Work Screen for Milling Machines a b d c e f g h i ...
Page 27: ...Getting Started PaveSmart 3D UM 27 Work Screen Mainline Concrete Paver a b c d f g h i j e ...
Page 30: ...PaveSmart 3D UM 30 Getting Started Work Screen Trimmer a b d c e f g h i j ...
Page 99: ...System Components Diagrams Software Description PaveSmart 3D UM 99 ...
Page 107: ...Troubleshooting PaveSmart 3D UM 107 ...
Page 136: ...PaveSmart 3D UM 136 Technical Data Mounting RAM mounting Parameter Data ...