Checking Instrument Setup Quality and Status
When to check?
Following survey best-practice is the key to maximum system accuracy with Leica PaveSmart
3D. Poorly positioned or orientated instruments may have a serious effect on product
quality.
This procedure should be carried out regularly, ideally during breaks in machine operations,
e.g. waiting for concrete, to ensure no undetected movement of the robots has occurred
(e.g. due to excessive vibrations, bad sub-ground under the tripod, high wind, temperature
cycling effects etc.). This is also very important when the instrument has been standing for
a long time (e.g. > 2 hr) at the same setup.
and Viva
instruments
Using the Tiepoint Check function from the
Work
dialog press
SENSOR
and define the
instrument with should be verified.
Refer to the MGuide User Manual Chapter 5 for further details.
or Viva can only
measure to the predefined point from the fixpoint job (see MGuide User Manual page 4-15).
The horizontal-, distance- and height accuracy settings are also defined in the same
or Viva dialog.
The fixpoint (reference point) job for the Robot setup is only stored on the
instrument. During the Robot Setup process (Free Station/Resection or
Known Point & Orientation) the user must preselect the desired Fixpoint
Job in the MGuide application. Please refer to the MGuide User Manual for
further information about working with Fixpoints.
Summary of Contents for MCR-900
Page 1: ...Leica PaveSmart 3D User Manual Version 5 0 English ...
Page 11: ...How to use this Manual PaveSmart 3D UM 11 ...
Page 21: ...Getting Started PaveSmart 3D UM 21 Work Screen for Milling Machines a b d c e f g h i ...
Page 27: ...Getting Started PaveSmart 3D UM 27 Work Screen Mainline Concrete Paver a b c d f g h i j e ...
Page 30: ...PaveSmart 3D UM 30 Getting Started Work Screen Trimmer a b d c e f g h i j ...
Page 99: ...System Components Diagrams Software Description PaveSmart 3D UM 99 ...
Page 107: ...Troubleshooting PaveSmart 3D UM 107 ...
Page 136: ...PaveSmart 3D UM 136 Technical Data Mounting RAM mounting Parameter Data ...