12
IR Remote Control
Rugby 200-3.2.1en
The Wall Mount Bracket
Assembly
Rugby200-10 wallmount2.eps
Allows the user to mount the Rugby
200 on a wall grid at the necessary
height. The rotating beam then
provides a reference height to hang
the ceiling grid.
To adjust the height, loosen the
adjustment knob on the side of the
bracket and slide the bracket up or
down until the desired height is
achieved.
A 5/8”-11 mounting hole is molded into
the back of the bracket for using the
Rugby 200 in the laydown position
mounted to a tripod.
The Ceiling Grid Target
Allows the user to visually detect the
rotating beam throughout the jobsite.
The ceiling grid target’s magnet
attaches to the bottom of the ceiling
grid. The grid can then be adjusted
until the beam is hitting the target’s
center line.
The Combination Laydown
and Wall Mount Bracket
Rugby200-11 wallmount2.eps
Allows the user to perform all the same
functions as the Wall Mount Bracket
but has additional features that allow
for fine adjustments to be made when
the Rugby 200 is mounted to the
bracket and used in the laydown
position.