46
Rugby 260SG / 270SG / 280DG, Troubleshooting
If none of the above suggestions results in a solution, contact your local dealer or
nearest authorized service center.
Grade stakes do
not match the
laser
•
Check for proper alignment of the axes.
•
Check level accuracy of the Rugby.
•
Check the grade stakes to verify their accuracy or to deter-
mine if they have moved.
Remote will not
turn on
Check and replace the batteries.
Remote will not
communicate with
the Rugby
•
Check that remote capability is enabled on the Rugby. (See
small icon on the main screen)
•
Check remote battery status.
•
Reduce distance and try again.
•
At longer distances, ensure the remote is in the “line of
sight” of the Rugby.
•
Position the remote more upright to improve distance.
Setup options
cannot be
changed
•
The Rugby is locked.
•
Unlock the Rugby in the setup screen.
Symptom