Rugby 260SG / 270SG / 280DG, Technical Data
75
11
Technical Data
Rugby 260SG /
270SG / 280DG
*
Accuracy defined at +25°C / +77°F.
** Battery life is dependent on many variables.
Description
Value
Horizontal self-leveling accuracy*
1.5 mm at 30 m (±1/16 inch at 100 ft)
Grade accuracy
3.0 mm at 30 m (±1/8 inch at 100 ft)
Self-leveling range
± 5°
Laser diode type
635 nm (visible red laser)
Operating temperature
-20° to +50°C (-4° to +122°F)
Storage temperature (without batteries) -40° to +70°C (-40° to +158°F)
Battery life**
70 hours (4 alkaline),
40 hours (NiMH pack)
Charging time
8 hours (approximately)
Dimensions (HWD)
197 x 248 x 175 mm (7.8 x 9.8 x 6.9”)
Weight with batteries
2.95 kg (6.5 lbs.)
Environmental
Waterproof to IP67 Standard