Rugby 320 SG
19
Troubleshooting
7
Troubleshooting
7.1
Display Screen Explanations
Leica Start-up Screen
•
Can be programmed to display customer’s name and
address.
Battery Status Screen
•
Displays on power-up
•
Displays also when batteries are empty.
Automatic Mode
•
Main Display Screen
•
Unit automatically self-levels.
Manual Mode
•
Unit will not self-level
•
Grade can be changed with the grade/arrow buttons.
Manual Mode with Grade
•
Unit will self-level to grades input, then lock in
manual mode.
•
Grade can be changed with the grade/arrow buttons.
H.I. Alert Warning
•
Unit has moved and elevation may have changed.
•
Press Power or Star to reset H.I. function.
•
Check unit’s elevation and adjust if required.
Servo Limit Warning
•
Unit is not level
•
Check setup and circular level vial.
Tilt Warning
•
Unit is tilted more than 30°.
Temperature Warning
•
Unit is too hot or cold to operate properly.
•
Shade unit if too hot.
•
Warm unit before continuing if too cold.
Negative Grade Disabled
•
The ability to enter negative grade has been disabled
in the second setup screen.