Rugby 410/420 DG
Setup
16
Manual Mode with
Grade
In Manual Mode with Grade, the display will alternately show the grade
entered for the X- and Y-axis and the crossed out level vial as shown
here:
In this mode, grade can be entered into either axis. The Rugby will self-
level to the grade input in the unit, then will lock into manual mode at
this grade.
)
Once locked in manual mode the self-leveling function is turned off.
If it is desired to change the manual grade shown, a new grade can be
entered (same as in automatic mode) and the Rugby will level to this new
grade, then lock in manual mode.
Wind Sensitivity
The Wind Sensitivity setting allows the Rugby to operate in adverse envi-
ronmental and windy conditions, while still ensuring maximum accuracy.
Beam Masking
Electronic Beam Masking allows the operator to turn off the laser beam
in specific quadrants to prevent interference with other operations on
the job.
Using the setup menu, the beam can be turned off in up to three
selected quadrants.
When a quadrant is turned off, the space will appear dark.
The sensitivity numbers can be set from 1 to 5. Select “1”
for calm conditions. Select “5” for very windy conditions.
Use the lowest setting for conditions present.
The quadrants selected can be either diagonals of
corners of the Rugby. This selection is made in the
second setup screen.
The settings for beam masking are normally not saved
when the Rugby is turned off. The Rugby can be made to
save the mask settings in the second setup screen.