BMM_BeepNormal - outputing an alarm signal (single beep)
BMM_BeepNormal............................................................................................................................................................................................................................................................................
mal
................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................ 11003
11003...............................................................................................................................................................................................................................................................BMM_BeepNor
C-Declaration
BMM_BeepNormal(void)
VB-Declaration
VB_BMM_BeepNormal()
ASCII-Request
%R1Q,11003:
ASCII-Response
%R1P,0,0:
RC
Remarks
This function produces a single beep with the configured intensity and frequency, which cannot be changed. If a
continuous signal is active, it will be stopped first.
Parameters
Return-Code Names and Return-Code Values
GRC_OK
0 Execution
successful.
See Also
BMM_BeepAlarm
IOS_BeepOn
IOS_BeepOff